DTC P0A78-284 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 284 | Motor inverter fail signal detection (overheat) |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-202 is not output. | A |
| P0A78-202 is also output. | B |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Only P0A78-284 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 503, 505, 547, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 504, 506, 549, 556, 808 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-279, 287, 548, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
| P0C19-306 | Drive Motor "A" Torque Delivered Performance |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Performance |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range/Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range/Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P0E71-344 | Generator Torque Delivered Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range/Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range/Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range/Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range/Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range/Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P314A-828 | Inverter Coolant Pump Speed Signal |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 503, 505, 547, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 504, 506, 549, 556, 808 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-279, 287, 548, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Performance |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range/Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range/Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P0E71-344 | Generator Torque Delivered Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range/Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range/Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range/Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | |
| 4.CHECK QUANTITY OF HV COOLANT |
Check the HV coolant level in the inverter reserve tank.
Check for HV coolant leaks.
| Result | Proceed to |
| No leaks are found and coolant level in the inverter reserve tank assembly is above the low line. | A |
| No leaks are found and coolant level in the inverter reserve tank assembly is below the low line. | B |
| Coolant leaks are evident. | C |
|
| ||||
|
| ||||
| A | |
| 5.CHECK COOLANT HOSE |
Check if the hoses of the cooling system are kinked or clogged.
|
| ||||
| OK | |
| 6.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE ELECTRIC COOLING FAN) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.
Perform the "Control the Electric Cooling Fan" Active Test.
Turn the power switch off.
|
| ||||
| OK | |
| 7.CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data Ambient Temperature using the intelligent tester.
Check if the freeze frame data Ambient Temperature is below freezing.
| Result | Proceed to |
| Ambient Temperature value is below freezing temperature of the HV coolant. | A |
| Ambient Temperature value is above freezing temperature of the HV coolant. | B |
Turn the power switch off.
|
| ||||
| A | |
| 8.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| C28-12 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-7 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| C28-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-10 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| C28-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 9.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C28-12 (GRFG) | Power switch off | 7.1 to 21.6 Ω |
| C28-7 (GSN) - C28-8 (GSNG) | Power switch off | 13.7 to 34.5 Ω |
| C28-10 (GCS) - C28-9 (GCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C28-12 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-7 (GSN) or C28-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-10 (GCS) or C28-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| C28-2 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-3 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| C28-4 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| C28-5 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 11.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C28-2 (MRFG) | Power switch off | 7.1 to 21.6 Ω |
| C28-3 (MSN) - C28-4 (MSNG) | Power switch off | 13.7 to 34.5 Ω |
| C28-6 (MCS) - C28-5 (MCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C28-2 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-3 (MSN) or C28-4 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-6 (MCS) or C28-5 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 12.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG1) from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG1) to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
|
| ||||
| A | |
| 13.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG2) from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable (for MG2).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG2) to the inverter with converter assembly.
Install the inverter terminal cover.
|
| ||||
|
| ||||
| A | |
| 14.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the motor cable from the inverter with converter assembly.
![]() |
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - a2-2 (U) | Power switch off | 139.1 to 153.7 mΩ |
| a2-2 (U) - a2-3 (V) | Power switch off | 139.1 to 153.7 mΩ |
| a2-3 (V) - a2-1 (W) | Power switch off | 139.1 to 153.7 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 15.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the motor cable from the inverter with converter assembly.
![]() |
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - a4-2 (U) | Power switch off | 172.5 to 190.7 mΩ |
| a4-2 (U) - a4-3 (V) | Power switch off | 172.5 to 190.7 mΩ |
| a4-3 (V) - a4-1 (W) | Power switch off | 172.5 to 190.7 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (for MG2) (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 16.CHECK FUSE (PCU) |
![]() |
Remove the PCU fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| PCU fuse terminal | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | PCU fuse |
Install the PCU fuse.
|
| ||||
| OK | |
| 17.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT) |
Check that the service plug grip is not installed.
Disconnect connector A47 from inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-28 (GND1) - Body ground | Power switch off | Below 1 Ω |
| A47-27 (GND2) - Body ground | Power switch off | Below 1 Ω |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-10 (+B) - Body ground | Power switch on (IG) | Same as auxiliary battery voltage |
| A47-9 (+B2) - Body ground | Power switch on (IG) | Same as auxiliary battery voltage |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 18.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - HYBRID VEHICLE CONTROL ECU) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
Disconnect connector A72 from the hybrid vehicle control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-8 (HTM+) - A72-24 (HTM+) | Power switch off | Below 1 Ω |
| A47-18 (HTM-) - A72-25 (HTM-) | Power switch off | Below 1 Ω |
| A47-7 (MTH+) - A72-23 (MTH+) | Power switch off | Below 1 Ω |
| A47-17 (MTH-) - A72-22 (MTH-) | Power switch off | Below 1 Ω |
| A47-6 (REQ+) - A72-31 (REQ+) | Power switch off | Below 1 Ω |
| A47-16 (REQ-) - A72-30 (REQ-) | Power switch off | Below 1 Ω |
| A47-5 (CLK+) - A72-33 (CLK+) | Power switch off | Below 1 Ω |
| A47-15 (CLK-) - A72-32 (CLK-) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A47-8 (HTM+) or A72-24 (HTM+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-18 (HTM-) or A72-25 (HTM-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-7 (MTH+) or A72-23 (MTH+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-17 (MTH-) or A72-22 (MTH-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-6 (REQ+) or A72-31 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-16 (REQ-) or A72-30 (REQ-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-5 (CLK+) or A72-33 (CLK+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-15 (CLK-) or A72-32 (CLK-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Hybrid Vehicle Control ECU) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-8 (HTM+) or A72-24 (HTM+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-18 (HTM-) or A72-25 (HTM-) - Body ground | Power switch on (IG) | Below 1 V |
| A47-7 (MTH+) or A72-23 (MTH+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-17 (MTH-) or A72-22 (MTH-) - Body ground | Power switch on (IG) | Below 1 V |
| A47-6 (REQ+) or A72-31 (REQ+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-16 (REQ-) or A72-30 (REQ-) - Body ground | Power switch on (IG) | Below 1 V |
| A47-5 (CLK+) or A72-33 (CLK+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-15 (CLK-) or A72-32 (CLK-) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the hybrid vehicle control ECU connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 19.CHECK HYBRID VEHICLE CONTROL ECU |
Disconnect connector A72 from the hybrid vehicle control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A72-24 (HTM+) - A72-25 (HTM-) | Power switch off | 80 to 170 Ω |
| A72-23 (MTH+) - A72-22 (MTH-) | Power switch off | 80 to 170 Ω |
| A72-31 (REQ+) - A72-30 (REQ-) | Power switch off | 80 to 170 Ω |
| A72-33 (CLK+) - A72-32 (CLK-) | Power switch off | 80 to 170 Ω |
| *a | Component without harness connected (Hybrid Vehicle Control ECU) |
Connect the hybrid vehicle control ECU connector.
|
| ||||
| OK | |
| 20.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 21.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 22.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 23.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C24-1 (GRF) | Power switch off | Below 1 Ω |
| C28-12 (GRFG) - C24-5 (GRFG) | Power switch off | Below 1 Ω |
| C28-7 (GSN) - C24-2 (GSN) | Power switch off | Below 1 Ω |
| C28-8 (GSNG) - C24-6 (GSNG) | Power switch off | Below 1 Ω |
| C28-10 (GCS) - C24-3 (GCS) | Power switch off | Below 1 Ω |
| C28-9 (GCSG) - C24-7 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C24-1 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-12 (GRFG) or C24-5 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-7 (GSN) or C24-2 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-8 (GSNG) or C24-6 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-10 (GCS) or C24-3 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-9 (GCSG) or C24-7 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 24.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 25.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C26-3 (MRF) | Power switch off | Below 1 Ω |
| C28-2 (MRFG) - C26-6 (MRFG) | Power switch off | Below 1 Ω |
| C28-3 (MSN) - C26-1 (MSN) | Power switch off | Below 1 Ω |
| C28-4 (MSNG) - C26-4 (MSNG) | Power switch off | Below 1 Ω |
| C28-6 (MCS) - C26-2 (MCS) | Power switch off | Below 1 Ω |
| C28-5 (MCSG) - C26-5 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C26-3 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-2 (MRFG) or C26-6 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-3 (MSN) or C26-1 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-4 (MSNG) or C26-4 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-6 (MCS) or C26-2 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-5 (MCSG) or C26-5 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 26.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-10 (+B) - Body ground | Power switch off | 10 kΩ or higher |
| A47-9 (+B2) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 27.REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS |
| NEXT | ||
| ||
| 28.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | ||
| ||
| 29.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the inverter with converter assembly (Click here).
![]() |
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG1) to the hybrid vehicle transaxle assembly.
Install the inverter with converter assembly.
|
| ||||
|
| ||||
| A | |
| 30.CHECK MOTOR CABLE (FOR MG1) |
Check that the service plug grip is not installed.
Remove the motor cable (Click here).
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG1) (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - a1-1 (W) | Power switch off | Below 1 Ω |
| a2-2 (U) - a1-2 (U) | Power switch off | Below 1 Ω |
| a2-3 (V) - a1-3 (V) | Power switch off | Below 1 Ω |
| a2-1 (W) - a1-2 (U) | Power switch off | 100 MΩ or higher |
| a2-2 (U) - a1-3 (V) | Power switch off | 100 MΩ or higher |
| a2-3 (V) - a1-1 (W) | Power switch off | 100 MΩ or higher |
Install the motor cable.
|
| ||||
| OK | ||
| ||
| 31.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG2) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG2).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG2) to the hybrid vehicle transaxle assembly.
|
| ||||
|
| ||||
| A | |
| 32.CHECK MOTOR CABLE (FOR MG2) |
Check that the service plug grip is not installed.
Remove the motor cable (Click here).
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG2) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG2) (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - a3-1 (W) | Power switch off | Below 1 Ω |
| a4-2 (U) - a3-3 (U) | Power switch off | Below 1 Ω |
| a4-3 (V) - a3-2 (V) | Power switch off | Below 1 Ω |
| a4-1 (W) - a3-3 (U) | Power switch off | 100 MΩ or higher |
| a4-2 (U) - a3-2 (V) | Power switch off | 100 MΩ or higher |
| a4-3 (V) - a3-1 (W) | Power switch off | 100 MΩ or higher |
Install the motor cable.
|
| ||||
| OK | ||
| ||
| 33.REPLACE HV COOLANT |
Replace the HV coolant with coolant having an appropriate concentration (appropriate freeze point) for the vehicle usage conditions (Click here).
| NEXT | ||
| ||