SMART ENTRY AND START SYSTEM (for Start Function) > Power Source Mode does not Change to ON (IG) |

| Problem Symptom | Data List Item | Active Test Item |
| Power source mode does not change to on (IG) but does change to on (ACC) | Power Source Control
| - |
| 1.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - NO. 1 INTEGRATION RELAY) |
Disconnect the A39 connector from the power management control ECU.
Disconnect the 2D and 2E connectors from the No. 1 integration relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A39-2 (IG2D) - 2D-3 | Always | Below 1 Ω |
| 2D-2 - Body ground | Always | Below 1 Ω |
| A39-2 (IG2D) or 2D-3 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.INSPECT NO. 1 INTEGRATION RELAY (IG2 RELAY) |
Remove the No. 1 integration relay (Click here).
Inspect the No. 1 integration relay (Click here).
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) |
Disconnect the G58 connector from the power management control ECU.
Disconnect the 3A and 3B connectors from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G58-2 (IG1D) - 3A-29 | Always | Below 1 Ω |
| 3B-8 - Body ground | Always | Below 1 Ω |
| G58-2 (IG1D) and 3A-29 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1 NO. 1 IND IG1 NO. 2 RELAY) |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly (Click here).
Measure the resistance according to the value(s) in the table below.

| *1 | for LHD | *2 | for RHD |
| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
| Tester Connection | Condition | Specified Condition |
| Auxiliary battery voltage not applied to terminals 3A-29 and 3B-8 | 10 kΩ or higher |
| Auxiliary battery voltage applied to terminals 3A-29 and 3B-8 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| Auxiliary battery voltage not applied to terminals 3A-29 and 3B-8 | 10 kΩ or higher |
| Auxiliary battery voltage applied to terminals 3A-29 and 3B-8 | Below 1 Ω |
|
| ||||
| OK | |
| 5.CHECK POWER MANAGEMENT CONTROL ECU |
![]() |
Reconnect the A39 and G58 power management control ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A39-2 (IG2D) - Body ground | Power switch on (ACC) → Power switch on (IG) | 1 V or less → 9 V or higher |
| G58-2 (IG1D) - Body ground | Power switch on (ACC) → Power switch on (IG) | 1 V or less → 9 V or higher |
| *a | Component with harness connected (Power Management Control ECU) |
|
| ||||
| OK | ||
| ||