DTC U029A-123 Lost Communication with Hybrid Battery Pack Sensor Module |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| U029A | 123 | Problem in serial communication between the battery smart unit and power management control ECU (1 trip detection) |
|

| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check for DTCs (Click here).
| Result | Proceed to |
| Only U029A-123 is output. | A |
| DTCs other than U029A-123 are also output. | B |
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
|
| ||||
| A | |
| 2.CHECK BATTERY SMART UNIT (IGCT VOLTAGE) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid battery exhaust duct .
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| M39-3 (IGCT) - M39-6 (GND) | Power switch on (IG) | 11 to 14 V |
| *a | Component with harness connected (Battery Smart Unit) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery exhaust duct.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY SMART UNIT) |
Check that the service plug grip is not installed.
Disconnect connector G57 from the power management control ECU (Click here).
Remove the No. 1 hybrid battery exhaust duct .
Disconnect connector M39 from the battery smart unit.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| G57-32 (BTH+) - M39-1 (BTH+) | Power switch off | Below 1 Ω |
| G57-33 (BTH-) - M39-4 (BTH-) | Power switch off | Below 1 Ω |
| M39-1 (BTH+) - M39-6 (GND) and Body ground | Power switch off | 10 kΩ or higher |
| M39-4 (BTH-) - M39-6 (GND) and Body ground | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Rear view of wire harness connector (to Battery Smart Unit) |
![]() |
Remove the IG2 No. 2 fuse, IGCT No. 2 fuse, AM2 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | IG2 No. 2 fuse |
| *3 | IGCT No. 2 fuse |
| *4 | AM2 fuse |
Disconnect all connectors from the power management control ECU.
Measure the resistance according to the value(s) in the table below.

| Tester Connection | Switch Condition | Specified Condition |
| G57-32 (BTH+) - G58-7 (AM21) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - G57-1 (AM22) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - A38-2 (+B2) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - A39-5 (+B1) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - A39-6 (MREL) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - A39-1 (IG2) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - G58-1 (ACCD) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) G58-2 (IG1D) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - A39-2 (IG2D) | Power switch off | 10 kΩ or higher |
| G57-32 (BTH+) - G57-14 (SPDI) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - G58-7 (AM21) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - G57-1 (AM22) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - A38-2 (+B2) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - A39-5 (+B1) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - A39-6 (MREL) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - A39-1 (IG2) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - G58-1 (ACCD) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - G58-2 (IG1D) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - A39-2 (IG2D) | Power switch off | 10 kΩ or higher |
| G57-33 (BTH-) - G57-14 (SPDI) | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to Power Management Control ECU) | - | - |
Connect the battery smart unit connector.
Install the No. 1 hybrid battery exhaust duct.
Connect the power management control ECU connectors.
|
| ||||
| OK | |
| 4.CHECK POWER MANAGEMENT CONTROL ECU |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid battery exhaust duct .
Disconnect connector M39 from the battery smart unit.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| M39-1 (BTH+) - M39-6 (GND) | Power switch on (IG) | 2.3 to 2.7 V |
| M39-4 (BTH-) - M39-6 (GND) | Power switch on (IG) | 2.3 to 2.7 V |
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| M39-1 (BTH+) - M39-4 (BTH-) | Power switch off | 4.4 to 5.4 kΩ |
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
Connect the battery smart unit connector.
Install the No. 1 hybrid battery exhaust duct.
|
| ||||
| OK | ||
| ||