Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P3004-132    High Voltage Power Resource

for Preparation Click here


DESCRIPTION

Refer to the description for DTC P0AE6-225 .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P3004
132
The inverter is not precharged.
  1. Hybrid battery junction block assembly
  2. Frame wire
  3. Inverter with converter assembly
  4. Hybrid vehicle control ECU
  5. HV battery
  6. Wire harness or connector

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AA6-526 .
Refer to the wiring diagram for DTC P0AE6-225 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

  3. When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch off and wait for 30 seconds or more.
  2. Turn the power switch on (READY) and wait for 30 seconds or more.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    Only P3004-132 is output or P3004-132 and DTCs other than the ones in the table below are also output.
    A
    DTCs shown in Table 1 are output simultaneously.
    B
    DTCs shown in Table 2 are output simultaneously.
    C


    Table 1 
    DTC No.
    Relevant Diagnosis
    P06E6-164
    Sensor Power Supply "C" Circuit/Open
    P0A1A-151, 658
    Generator Control Module
    P0A1B-786
    Drive Motor "A" Control Module
    P0A1D-148
    Hybrid Powertrain Control Module
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE6-225
    Hybrid Battery Precharge Contactor Control Circuit Low
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P0CA3-442
    DC/DC Converter Step Up Voltage Performance
    P0D2E-586
    Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance
    P0D2F-266
    Drive Motor "A" Inverter Voltage Sensor Circuit Low
    P0D30-267
    Drive Motor "A" Inverter Performance
    P1C2A-155
    Generator A/D Converter Circuit
    P1C73-512
    Sensor Standard Voltage "F" Circuit/Open
    P1CA6-156
    Generator Control Module Malfunction
    P1CA7-193
    Drive Motor Control Module Malfunction
    P2511-149
    HV CPU Power Relay Sense Circuit Intermittent No Continuity
    P3004-131, 800, 801
    High Voltage Power Resource
    P3133-659
    Communication Error from Generator to Drive Motor "A"
    P3134-661
    Communication Error from Drive Motor "A" to Generator
    P324E-788
    MG-ECU Power Relay Intermittent Circuit
    U0110 (all INF codes)*1
    Lost Communication with Drive Motor Control Module "A"

    Table 2 
    DTC No.
    Relevant Diagnosis
    P0A95-123
    High Voltage Fuse
    P0ABF-123
    Hybrid Battery Pack Current Sensor Circuit
    P0AC0-123
    Hybrid Battery Pack Current Sensor Circuit Range / Performance
    P0AC1-123
    Hybrid Battery Pack Current Sensor "A" Circuit Low
    P0AC2-123
    Hybrid Battery Pack Current Sensor "A" Circuit High
    P0AFC-123
    Hybrid Battery Pack Sensor Module
    P0B3D-123
    Hybrid Battery Voltage Sensor "A" Circuit Low
    P0B42-123
    Hybrid Battery Voltage Sensor "B" Circuit Low
    P0B47-123
    Hybrid Battery Voltage Sensor "C" Circuit Low
    P0B4C-123
    Hybrid Battery Voltage Sensor "D" Circuit Low
    P0B51-123
    Hybrid Battery Voltage Sensor "E" Circuit Low
    P0B56-123
    Hybrid Battery Voltage Sensor "F" Circuit Low
    P0B5B-123
    Hybrid Battery Voltage Sensor "G" Circuit Low
    P0B60-123
    Hybrid Battery Voltage Sensor "H" Circuit Low
    P0B65-123
    Hybrid Battery Voltage Sensor "I" Circuit Low
    P0B6A-123
    Hybrid Battery Voltage Sensor "J" Circuit Low
    P0B6F-123
    Hybrid Battery Voltage Sensor "K" Circuit Low
    P308A-123
    Hybrid Battery Voltage Sensor All Circuits Low
    U029A-123
    Lost Communication with Hybrid Battery Pack Sensor Module

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P3004-132 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)

C
GO TO DTC CHART (HYBRID BATTERY SYSTEM) (Click here)
A


2.CHECK FREEZE FRAME DATA (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read the freeze frame data of DTC P3004-132.

    Result:

    Result
    Proceed to
    All of the following conditions are met:
    1. Difference between HV battery voltage (Power Resource VB) and pre-boost voltage (VL-Voltage before Boosting) is 35 V or less.
    2. Difference between HV battery voltage (Power Resource VB) and post-boost voltage (VH-Voltage after Boosting) is more than 60 V.
    3. Difference between pre-boost voltage (VL-Voltage before Boosting) and post-boost voltage (VH-Voltage after Boosting) is more than 80 V.
    A
    In addition to the above conditions, HV battery current (Batt Pack Current Val) is 3 A or more.
    B
    Other than above
    C

  1. Turn the power switch off.



B
GO TO DTC CHART (P3004-800) (Click here)

C
Go to step 3
A

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS (Click here)  

3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)


    A279820E01
  1. Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors (Click here).
    Text in Illustration 
    *A
    for LHD
    *B
    for RHD

    OK:
    The connectors are connected securely and there are no contact pressure problems.



NG
CONNECT SECURELY
OK


4.CHECK INVERTER WITH CONVERTER ASSEMBLY (FRAME WIRE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258649E05
  1. Check the connector P1 connection condition between the frame wire and the inverter with converter assembly.

Torque:
Bolt A:
8.0 N*m{ 82 kgf*cm , 71 in.*lbf }
Bolt B:
9.2 N*m{ 94 kgf*cm , 81 in.*lbf }

  1. Disconnect connector P1 of the frame wire from the inverter with converter assembly.

  1. Check for arc marks on the terminals of the frame wire.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the frame wire to the inverter with converter assembly.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


5.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (FRAME WIRE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid vehicle battery cover panel LH .



    A267592E04
  1. Check the connector P5 and connector P4 connection condition between the frame wire and the hybrid battery junction block assembly.

  1. Disconnect connector P5 and connector P4 of the frame wire from the hybrid battery junction block assembly.

  1. Check for arc marks on the terminals of the frame wire.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the frame wire to the hybrid battery junction block assembly.

  1. Install the No. 1 hybrid vehicle battery cover panel LH.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


6.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258649E06
  1. Disconnect connector P1 of the frame wire from the inverter with converter assembly.

  1. Remove the No. 1 hybrid vehicle battery cover panel LH .



    A267592E04
  1. Disconnect connector P5 and connector P4 of the frame wire from the hybrid battery junction block assembly.



    A264088E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    P5-1 (CBI) - P1-2 (CBI)
    Power switch off
    Below 1 Ω
    P4-1 (CEI) - P1-1 (CEI)
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Frame wire
    (Inverter with Converter Assembly Side)
    *b
    Frame wire
    (Hybrid Battery Junction Block Assembly Side)

  1. Connect the frame wire to the hybrid battery junction block assembly.

  1. Install the No. 1 hybrid vehicle battery cover panel LH.

  1. Connect the frame wire to the inverter with converter assembly.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



NG
REPLACE FRAME WIRE (Click here)
OK


7.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (HV BATTERY HIGH VOLTAGE TERMINAL CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 2 hybrid battery shield sub-assembly .



    A267591
  1. Check the connections between the HV battery high voltage terminals and the hybrid battery junction block assembly.

    Specified Condition:
    5.4 N*m (55 kgf*cm, 48 in.*lbf)

  1. Disconnect the HV battery high voltage terminals from the hybrid battery junction block assembly.

  1. Check for arc marks on the terminals of the HV battery high voltage terminals.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the HV battery high voltage terminals.

  1. Install the No. 2 hybrid battery shield sub-assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


8.CHECK HV BATTERY

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 2 hybrid battery shield sub-assembly .



    A268249E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A-1 (+) - Service plug grip terminal 1
    Power switch off
    66 V or higher
    c1-1 (-) - Service plug grip terminal 2
    Power switch off
    54 V or higher

    CAUTION:
    Do not allow the probes of the electrical tester to contact each other during this inspection.

  1. Install the No. 2 hybrid battery shield sub-assembly.



NG
REPLACE HV BATTERY (Click here)
OK


9.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector G80 from the hybrid vehicle control ECU.

  1. Remove the No. 1 hybrid vehicle battery cover panel LH .

  1. Disconnect the connector M40 that drives the system main relay of the hybrid battery junction block assembly.

    HINT:
    Before disconnecting the connector M40 that drives the system main relay of the hybrid battery junction block assembly, make sure that the connector is securely engaged.



    A260191E42
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    G80-4 (SMRB) - M40-1 (SMRB)
    Power switch off
    Below 1 Ω
    G80-3 (SMRP) - M40-4 (SMRP)
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Hybrid Vehicle Control ECU)
    *b
    Rear view of wire harness connector
    (to Hybrid Battery Junction Block Assembly)

  1. Connect the hybrid battery junction block assembly connector.

  1. Install the No. 1 hybrid vehicle battery cover panel LH.

  1. Connect the hybrid vehicle control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A259731E21
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P5-1 (CBI) - A-1 (+)
    Auxiliary battery voltage is applied between terminals M40-1 (SMRB) and M40-2 (GND)
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Hybrid Battery Junction Block Assembly)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    M40-1 (SMRB) - M40-2 (GND)
    -40 to 80 °C (-40 to 176°F)
    25.0 to 59.0 Ω

  1. Install the hybrid battery junction block assembly.



NG
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
OK


11.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A259731E22
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P4-1 (CEI) - c1-1 (-)
    Auxiliary battery voltage is applied between terminals M40-4 (SMRP) and M40-2 (GND)
    28.5 to 31.5 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Hybrid Battery Junction Block Assembly)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    M40-4 (SMRP) - M40-2 (GND)
    -40 to 80 °C (-40 to 176°F)
    112 to 274 Ω

  1. Install the hybrid battery junction block assembly.



NG
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
OK


12.CHECK FOR INTERMITTENT PROBLEMS
(Click here)

NEXT


13.CLEAR DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read and record the DTCs and freeze frame data.

  1. Clear DTCs and freeze frame data.

  1. Turn the power switch off.


NEXT


14.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (READY).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    No DTCs are output.
    A
    DTC P3004-131 is output.
    B
    DTC P3004-132 is output.
    C

    HINT:
    Because P3004-131 uses 2-trip detection logic, the DTC detection conditions need to be met 2 times.

  1. Turn the power switch off.



B
GO TO DTC CHART (P3004-131) (Click here)

C
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS (Click here)