DESCRIPTION

The power management control ECU controls the back-up lights via the BKUP LP relay.

WIRING DIAGRAM


E233298E02


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses and bulbs for circuits related to this system before performing the following inspection procedure.

1.CHECK DTC OUTPUT (HYBRID CONTROL SYSTEM)
  1. Check for DTCs (Click here).

    OK:
    Hybrid control system DTCs are not output.



NG
GO TO HYBRID CONTROL SYSTEM (Click here)
OK


2.INSPECT BKUP LP RELAY


    B060778E87
  1. Remove the BKUP LP relay from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω



NG
REPLACE BKUP LP RELAY
OK


3.CHECK HARNESS AND CONNECTOR (BKUP LP RELAY - IG1 NO. 1 RELAY AND BODY GROUND)
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 3 - Body ground
    Power switch on (IG)
    11 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 2 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (BKUP LP RELAY - BACK UP LIGHT LH AND BACK UP LIGHT RH)
  1. Disconnect the M5 rear combination light assembly LH connector.

  1. Disconnect the M6 rear combination light assembly RH connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 5 - M5-2 (B)
    Always
    Below 1 Ω
    Relay terminal 5 - M6-2 (B)
    Always
    Below 1 Ω
    Relay terminal 5 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (BKUP LP RELAY - POWER MANAGEMENT CONTROL ECU)
  1. Disconnect the A38 power management control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 1 - A38-15 (BL)
    Always
    Below 1 Ω
    Relay terminal 1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)