Using SST, install the heated oxygen sensor onto the front exhaust pipe.
Text in Illustration
*a
Fulcrum Length 30 mm (1.18 in.)
*b
Fulcrum Length 260 mm (10.2 in.)
SST
09224-00010
Torque:
without SST:
44 N*m{
449 kgf*cm
, 32 ft.*lbf
}
with SST:
39 N*m{
398 kgf*cm
, 29 ft.*lbf
}
NOTICE:
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.) and a torque wrench with a fulcrum length of 260 mm (10.2 in.) (Click here).
The "with SST" torque value is effective when SST is parallel to the torque wrench.