Home › Drivetrain › P510 HYBRID TRANSMISSION / TRANSAXLE › MOTOR CABLE

MOTOR CABLE > REMOVAL

for Preparation Click here



1. REMOVE INVERTER WITH CONVERTER ASSEMBLY
(Click here)


2. REMOVE INVERTER BRACKET ASSEMBLY

CAUTION:
Wear insulated gloves.



    A268005
  1. Remove the bolt and separate the motor cable protector.



    A268006
  1. Disconnect the 2 wire harness clamps.



    A268007
  1. Remove the 2 bolts and separate the inverter reservoir tank assembly.



    A268008
  1. Remove the bolt and disconnect the earth wire.



    A268009
  1. Remove the 4 bolts and inverter bracket assembly.



3. DISCONNECT TRANSMISSION CONTROL CABLE ASSEMBLY


    C249716E01
  1. Disconnect the transmission control cable assembly from the transmission control cable clamp and transmission control cable support.
    Text in Illustration 
    *1
    Transmission Control Cable Clamp
    *2
    Transmission Control Cable Support



4. DISCONNECT WIRE HARNESS


    C249717
  1. Disconnect the 3 clamps and No. 2 engine wire.



    C249718
  1. Remove the 2 bolts, clamp and wire harness from the hybrid vehicle transaxle assembly.



5. REMOVE MOTOR CABLE

CAUTION:
Wear insulated gloves.



    C249719
  1. Disconnect the 4 clamps and motor cable from the hybrid vehicle transaxle assembly.



  1. Remove the motor cable (for MG 2).



      C249720
    1. Remove the 2 bolts and slide the connector shell back.



    2. C249721
    3. Disengage the 2 claws to remove the terminal cap from the hybrid vehicle transaxle assembly.



    4. C249722
    5. Disconnect the 3 bolts and motor cable from the hybrid vehicle transaxle assembly.



  1. Remove the motor cable (for MG 1).



      C249723
    1. Remove the 2 bolts and slide the connector shell back.



    2. C249724
    3. Disengage the 2 claws to remove the terminal cap from the hybrid vehicle transaxle assembly.



    4. C249725
    5. Remove the 3 bolts and motor cable from the hybrid vehicle transaxle assembly.