This circuit is the power source circuit for the combination meter assembly (meter circuit plate). This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.
Inspect the fuses of circuits related to this system before performing the following procedure.
Disconnect the F6 combination meter assembly (meter circuit plate) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-28 (ES) - Body ground | Always | Below 1 Ω |
| F6-40 (EP) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-21 (IG+) - Body ground | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |
| F6-22 (B) - Body ground | Power switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG