Home › Drivetrain › P610 HYBRID TRANSMISSION / TRANSAXLE › ELECTRONIC SHIFT LEVER SYSTEM
RM3210E _52 Drivetrain _047503 P610 HYBRID TRANSMISSION / TRANSAXLE _0243554 ELECTRONIC SHIFT LEVER SYSTEM J

P610 HYBRID TRANSMISSION / TRANSAXLE  ELECTRONIC SHIFT LEVER SYSTEM  Shift Sensor Circuit  


PROCEDURE

1.CHECK DIAGNOSIS RELATED INFORMATION (HYBRID CONTROL)
a.

Check for diagnosis related information.

Click hereDrivetrain>P610 HYBRID TRANSMISSION / TRANSAXLE>ELECTRONIC SHIFT LEVER SYSTEM>UTILITY

Result:
Result Proceed to
No diagnosis related information is output. A
The diagnosis related information in the table below is output. B


Diagnosis Related Information
P181B62



A

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (READY).


c.

With the brake pedal depressed, slowly move the shift lever as follows to select each shift position: N → R → N → D → B.

HINT:

Wait with each state selected for 5 seconds or more.



d.

Push the P position switch (transmission shift main switch) to select park (P).


e.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

Powertrain > Hybrid Control > Trouble Codes
50001 397

f.

Check for DTCs.

Result:
Result Proceed to
DTCs are not output. A
DTCs are output. B



g.

Turn the power switch off.



A

3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)

B

3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
a.

Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

A380420C01
0.135,0.094 0.448,0.292 0.313,0.198 10 false *A 3.604,0.073 3.917,0.271 0.313,0.198 10 false *B
*A for LHD *B for RHD


OK:

The connectors are connected securely and there are no contact pressure problems.



Result:
Proceed to
OK
NG



OK

4.CHECK CONNECTOR CONNECTION CONDITION (SHIFT LOCK CONTROL UNIT ASSEMBLY)

NG

CONNECT SECURELY

4.CHECK CONNECTOR CONNECTION CONDITION (SHIFT LOCK CONTROL UNIT ASSEMBLY)
a.

Check the connector connections and contact pressure of the relevant terminals for the shift lock control unit assembly connector.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

The connector is connected securely and there are no contact pressure problems.



Result:
Proceed to
OK
NG



OK

NG

CONNECT SECURELY