Home › Brake › BRAKE (REAR) › REAR BRAKE FLEXIBLE HOSE
RM3210E _54 Brake _047537 BRAKE (REAR) _0244655 REAR BRAKE FLEXIBLE HOSE A

BRAKE (REAR)  REAR BRAKE FLEXIBLE HOSE  INSTALLATION  


CAUTION / NOTICE / HINT

NOTICE:

When reusing the rear flexible hoses, use the identification marks created during removal to install each rear flexible hose to its original position.


HINT:
·

Use the same procedure for the RH side and LH side.

·

The following procedure is for the LH side.



PROCEDURE

Hide 47319F 1.INSTALL REAR FLEXIBLE HOSE

NOTICE:

When installing the rear flexible hose, minimize twisting of the hose.


a.
C345988C02
0.583,0.5 0.708,0.5 0.708,0.5 0.708,0.76 false 1.51,0.344 1.823,0.5 0.313,0.156 10 false *a 0.417,0.417 0.729,0.573 0.313,0.156 10 false *b
*a Torque Wrench Fulcrum Length
*b Union Nut Wrench


Install the rear flexible hose with a new clip.

NOTICE:

Install the clip as far as it will go.



b.

Using a union nut wrench, connect the brake line to the rear flexible hose while holding the rear flexible hose with a wrench.

Torque:
Specified tightening torque : 15.2 N*m (155 kgf*cm, 11 ft.*lbf)

NOTICE:
·

Do not kink or damage the brake line.

·

Do not allow any foreign matter such as dirt or dust to enter the brake line from the connecting parts.



HINT:
·

Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

When using a union nut wrench (fulcrum length of 22 mm (0.866 in.)) + torque wrench (fulcrum length of 162 mm (6.38 in.)):

13.38 N*m (136 kgf*cm, 10 ft.*lbf)




c.

Install the rear flexible hose with the bolt.

Torque:
29 N*m (296 kgf*cm, 21 ft.*lbf)


d.

Install the rear flexible hose to the rear disc brake cylinder assembly with a new union bolt and a new gasket.

Torque:
33.3 N*m (340 kgf*cm, 25 ft.*lbf)

NOTICE:

Install the rear flexible hose lock securely into the lock hole in the rear disc brake cylinder assembly.



Hide 2.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

a.

Connect the reservoir level switch connector.


b.

Connect the cable to the negative (-) auxiliary battery terminal.

Click herePower Source / Network>2ZR-FXE BATTERY / CHARGING>AUXILIARY BATTERY>INSTALLATION