HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM  P0CA300  DC/DC Converter Step Up Voltage Performance  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC indicates that it has been detected that the VH voltage cannot be boosted as commanded due to malfunction of the boost converter system. The cause of this malfunction may be one of the following:

Internal inverter malfunction

Inverter with converter assembly internal circuit malfunction


Inverter low-voltage circuit malfunction

The connectors are not connected properly



DESCRIPTION

The boost converter boosts the 201.6 V DC from the HV battery to a maximum of approximately 600 V DC. The inverter converts the voltage that has been boosted by the boost converter into alternating current, which is used for driving generator (MG1) and motor (MG2). When a motor or generator operates as a generator, the alternating current that it creates is converted into direct current by the inverter. Then the boost converter drops this voltage to direct current of approximately 201.6 V in order to charge the HV battery.

A105188E13
6.302,1.938 6.49,2.26 false 2.542,0.417 4.708,0.667 2.167,0.25 10 false Inverter with Converter Assembly 1.375,0.979 2.427,1.208 1.052,0.229 10 false Boost Converter 0.073,2.063 0.573,2.49 0.5,0.427 10 false HV Battery 0.594,3.948 1.667,4.375 1.073,0.427 10 false Before boosting direct current 3.167,3.948 4.167,4.365 1,0.417 10 false After boosting direct current 5.469,4.167 6.667,4.573 1.198,0.406 10 false After converting alternating current 1.729,3.083 3,3.323 1.271,0.24 10 false Voltage Conversion 6.042,2.271 7.104,2.604 1.063,0.333 10 false Motor Generator

The motor generator control ECU (MG ECU) uses a voltage sensor (VL) that is built into the boost converter to detect the high voltage before it is boosted. It also uses a voltage sensor (VH) that is built into the inverter to detect the high voltage after it is boosted. Based on the voltage before and after it is boosted, the motor generator control ECU (MG ECU) controls the operation of the boost converter to boost the voltage to the target voltage.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0CA300 DC/DC Converter Step Up Voltage Performance Abnormal voltage execution value:
Boosting cannot be performed as requested due to a boost converter system malfunction.
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Comes on Master Warning Light:
Comes on

HINT:

With the vehicle stopped, apply the parking brake and turn the power switch on (READY).

With park (P) selected, depress the brake pedal firmly, and quickly and fully depress the accelerator pedal.

Immediately after the accelerator pedal is fully depressed, "VH-Voltage after boosting" will be between 400 and 600 V.


Related Data List
DTC No. Data List
P0CA300
·

VL Voltage

·

VH Voltage



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Turn the power switch on (READY) and wait for 5 seconds or more.

7.

Depress the accelerator pedal of the vehicle with the engine stopped and park (P) selected to start the engine.

NOTICE:

As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.


8.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

9.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P0CA300 only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid control system in the tables below are output. B
DTCs of motor generator control system in the tables below are output. C


Table 1
Malfunction Content Relevant DTC
Insulation Malfunction P1C7C49 Hybrid/EV Battery Voltage System (A/C Area) Insulation Resistance Decreased
P1C7D49 Hybrid/EV Battery Voltage System (Hybrid/EV Battery Area) Insulation Resistance Decreased
P1C7E49 Hybrid/EV Battery Voltage System (Transaxle Area) Insulation Resistance Decreased
P1C7F49 Hybrid/EV Battery Voltage System (Direct Current Area) Insulation Resistance Decreased

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1A47 Generator Control Module
P0A1A49 Drive Motor "A" Control Module
P0A1B1F Drive Motor "B" Control Module
P1C2A1C Hybrid Powertrain Control Module
P1C2A49 Generator A/D Converter Circuit
P1C2B1C Drive Motor "A" A/D Converter Circuit
P1C2B49 Drive Motor "B" A/D Converter Circuit
P313383 Generator Control Module Malfunction
P313386 Drive Motor Control Module Malfunction
P313387 Drive Motor "B" Control Module Malfunction
P313483 Generator Position Sensor Angle Malfunction
P313486 Drive Motor "A" Position Sensor Angle Malfunction
P313487 Drive Motor "B" Position Sensor Angle Malfunction
Hybrid control system P0A1B49 Generator Position Sensor REF Signal Cycle Malfunction
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
Communication malfunction Motor generator control system P312487 Lost Communication between Drive Motor "A" and HV ECU Missing Message
Hybrid control system P312387 Lost Communication with Missing Message
Sensor and actuator circuit malfunction Motor generator control system P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A3F21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum
P0A3F22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum
P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold
P0A4B21 Generator Position Sensor Signal Amplitude < Minimum
P0A4B22 Generator Position Sensor Signal Amplitude > Maximum
P0A6012 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery
P0A6014 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open
P0A601C Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range
P0A6312 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery
P0A6314 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open
P0A631C Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range
P0BE512 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery
P0BE514 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open
P0BE528 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BE912 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery
P0BE914 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open
P0BE928 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BED12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery
P0BED14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open
P0BED28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BFD62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure
P0C5013 Drive Motor "A" Position Sensor Circuit "A" Circuit Open
P0C5016 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5017 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5A13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open
P0C5A16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5A17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C6413 Generator Position Sensor Circuit "A" Circuit Open
P0C6416 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C6417 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C6913 Generator Position Sensor Circuit "B" Circuit Open
P0C6916 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C6917 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0D2D16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
P0D2D17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P0DFA62 Generator Phase U-V-W Current Sensor Signal Compare Failure
P0E0012 Generator Phase U Current Sensor Circuit Short to Battery
P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open
P0E0028 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0412 Generator Phase V Current Sensor Circuit Short to Battery
P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open
P0E0428 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0812 Generator Phase W Current Sensor Circuit Short to Battery
P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open
P0E0828 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E3116 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold
P0E3117 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold
P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground
P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open
P0E511C DC/DC Converter Current Sensor Circuit Voltage Out of Range
P0E512A DC/DC Converter Current Sensor Signal Stuck In Range
P1CAC49 Generator Position Sensor Internal Electronic Failure
P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
Hybrid control system P0C7600 Hybrid/EV Battery System Discharge Time Too Long
P0D2D1C Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range
P0E311C Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range
P1C2D62 Drive Motor "A" Inverter before Boosting Voltage Sensor Signal Compare Failure
System malfunction Motor generator control system P0A9000 Drive Motor "A" Performance
P0A9200 Hybrid Generator Performance
P0BFF1D Drive Motor "A" Circuit Current Out of Range
P0C1900 Drive Motor "A" Execution Torque Performance
P0E7100 Generator Execution Torque Performance
P1CA51D Hybrid Generator Circuit Current Out of Range

HINT:
·

P0CA300 may be output as a result of the malfunction indicated by the DTCs above.

1.

The chart above is listed in inspection order of priority.

2.

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

C

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR