The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
82121
2.DISCONNECT ENGINE WIRE
Disengage the 2 claws and disconnect the engine wire from the battery current sensor holder.
Disconnect the battery state sensor assembly connector.
3.REMOVE AUXILIARY BATTERY
G3834
4.REMOVE SERVICE PLUG GRIP
51444C
5.REMOVE REAR MOTOR UNDER COVER LH
6.DRAIN COOLANT (for Inverter)
12601B
7.REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY
8.REMOVE WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY
55737B
9.REMOVE NO. 1 HEATER AIR DUCT SPLASH SHIELD SEAL (for LHD)
55738D
10.REMOVE NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for RHD)
55735A
11.REMOVE WATER GUARD PLATE LH
55736D
12.REMOVE COWL BODY MOUNTING REINFORCEMENT LH
55701J
13.REMOVE OUTER COWL TOP PANEL SUB-ASSEMBLY
89661
14.REMOVE ECM
74404A
15.REMOVE BATTERY CLAMP SUB-ASSEMBLY
Remove the 3 bolts and battery clamp sub-assembly.
82121
16.DISCONNECT ENGINE WIRE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Remove the No. 1 relay block cover.
Disconnect the 3 No. 1 engine room relay block and No. 1 junction block assembly connectors.
Disengage the 2 claws.
Move each lock lever as shown in the illustration and disconnect the 2 inverter with converter assembly connectors.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Insulate the disconnected terminals with insulating tape.
Do not touch the waterproof seal or terminals of the connector.
Remove the bolt.
Disengage the clamp (A) and remove the inverter protector.
Disengage the clamp (B).
Remove the bolt.
Disengage the 2 clamps and disconnect the engine wire.
17.REMOVE CONNECTOR COVER ASSEMBLY
Wear insulated gloves.
| *a | Bolt (A) |
| *b | Bolt (B) |
Remove the bolt (B).
Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.
Do not touch the connector cover assembly waterproof seal.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
18.CHECK TERMINAL VOLTAGE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.
0 V
Use a measuring range of DC 750 V or more on the voltmeter.
19.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY
Wear insulated gloves.
Temporarily install the connector cover assembly to the inverter with converter assembly.
Using a T25 "TORX" socket wrench, install the bolt.
Do not touch the waterproof seal of the connector cover assembly.
821H1
20.DISCONNECT HV FLOOR UNDER WIRE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
| *a | Waterproof Seal |
Remove the bolt and disconnect the HV floor under wire from the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Insulate the disconnected terminals with insulating tape.
Disengage the 2 clamps.
82311A
21.DISCONNECT AIR CONDITIONING WIRE
Wear insulated gloves.
| *a | Waterproof Seal |
Remove the 2 bolts and disconnect the air conditioning wire from the inverter with converter assembly.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Disengage the clamp.
22.REMOVE WIRE HARNESS CLAMP BRACKET
Remove the nut and wire harness clamp bracket.
82123
23.DISCONNECT NO. 3 ENGINE WIRE
Wear insulated gloves.
Remove the bolt.
Remove the bolt.
Disengage the 2 claws and open the No. 3 engine wire terminal cover.
Remove the nut.
Disengage the clamp and disconnect the No. 3 engine wire from the inverter with converter assembly.
G922C
24.DISCONNECT OUTLET NO. 1 INVERTER COOLING HOSE
Slide the clip and disconnect the outlet No. 1 inverter cooling hose from the inverter with converter assembly.
Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
G922AA
25.DISCONNECT INLET NO. 1 INVERTER COOLING HOSE
Slide the clip and disconnect the inlet No. 1 inverter cooling hose from the inverter with converter assembly.
Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
G9221
26.REMOVE INVERTER COVER
Wear insulated gloves.
| *a | Interlock |
| *b | Waterproof Seal |
Remove the 2 bolts and inverter cover from the inverter with converter assembly.
Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.
Do not touch the waterproof seal of the inverter cover.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
When removing the inverter cover, do not pull the areas (A) as they may deform.
Make sure that the interlock is installed to the inverter cover.
| *1 | Inverter Cover |
| *a | Screw |
Do not remove or excessively tighten the screw of the inverter cover.
Although the inverter cover may feel loose, this is not due to a malfunction.
If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.
G1148
27.DISCONNECT MOTOR CABLE
Wear insulated gloves.
Using an insulated tool, remove the 6 bolts.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
| *a | Waterproof Seal |
Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.
G9200
28.REMOVE INVERTER WITH CONVERTER ASSEMBLY
Wear insulated gloves.
Remove the 5 bolts, 2 nuts and inverter with converter assembly.
When removing the inverter with converter assembly, be careful not to damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.
G9214
29.REMOVE NO. 1 INVERTER BRACKET
| *a | Wooden Block |
Set the inverter with converter assembly on wooden blocks.
Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.
Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.
G9215
30.REMOVE NO. 2 INVERTER BRACKET
| *a | Wooden Block |
Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.
31.REMOVE WIRE HARNESS CLAMP BRACKET
Remove the 2 bolts and 2 wire harness clamp brackets from the inverter with converter assembly.
Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.
Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.