Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER
RM3210E _51 Engine / Hybrid System _047524 HYBRID / BATTERY CONTROL _0244765 INVERTER WITH CONVERTER A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link

*1: When performing learning using the GTS.

Click here(Click here)

Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Lane departure alert system (w/ Steering Control) (Click here)
Intelligent clearance sonar system*1
Simple intelligent parking assist system*1
Pre-crash safety system
Parking assist monitor system (Click here)
Initialize back door lock Power door lock control system (Click here)
Replacement of inverter with converter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


(Click here)
for SFI system (w/ Canister Pump Module)

Replacement of ECM


Perform Vehicle Identification Number (VIN) registration MIL comes on (Click here)
for SFI system (w/o Canister Pump Module)

Replacement of ECM


Perform Vehicle Identification Number (VIN) or frame number registration (Click here)

CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

·
A340358

To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.



PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 82121 2.DISCONNECT ENGINE WIRE

a.
A373689

Disengage the 2 claws and disconnect the engine wire from the battery current sensor holder.


b.

Disconnect the battery state sensor assembly connector.


Hide 51444C 5.REMOVE REAR MOTOR UNDER COVER LH

Hide 12601B 7.REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY

Hide 8.REMOVE WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY

Hide 55737B 9.REMOVE NO. 1 HEATER AIR DUCT SPLASH SHIELD SEAL (for LHD)

Hide 55738D 10.REMOVE NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for RHD)

Hide 55735A 11.REMOVE WATER GUARD PLATE LH

Hide 55736D 12.REMOVE COWL BODY MOUNTING REINFORCEMENT LH

Hide 55701J 13.REMOVE OUTER COWL TOP PANEL SUB-ASSEMBLY

Hide 74404A 15.REMOVE BATTERY CLAMP SUB-ASSEMBLY

a.
A376301

Remove the 3 bolts and battery clamp sub-assembly.


Hide 82121 16.DISCONNECT ENGINE WIRE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A376302

Remove the No. 1 relay block cover.


b.
A376303

Disconnect the 3 No. 1 engine room relay block and No. 1 junction block assembly connectors.


c.

Disengage the 2 claws.


d.
A376292

Move each lock lever as shown in the illustration and disconnect the 2 inverter with converter assembly connectors.

NOTICE:
·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.

·

Do not touch the waterproof seal or terminals of the connector.




e.
A376311N01
1.302,0.417 1.458,0.615 0.156,0.198 10 true A 1.427,1.844 1.583,2.042 0.156,0.198 10 true B

Remove the bolt.


f.

Disengage the clamp (A) and remove the inverter protector.


g.

Disengage the clamp (B).


h.

Remove the bolt.

A375967


i.

Disengage the 2 clamps and disconnect the engine wire.


Hide 17.REMOVE CONNECTOR COVER ASSEMBLY

CAUTION:

Wear insulated gloves.


a.
A376294C06
2.063,1.417 2.313,1.615 0.25,0.198 10 true *a 1.875,0.5 2.125,0.698 0.25,0.198 10 true *b
*a Bolt (A)
*b Bolt (B)


Remove the bolt (B).


b.

Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




Hide 18.CHECK TERMINAL VOLTAGE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A376295

Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

Standard Voltage:

0 V


HINT:

Use a measuring range of DC 750 V or more on the voltmeter.



Hide 19.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

CAUTION:

Wear insulated gloves.


a.
A376296

Temporarily install the connector cover assembly to the inverter with converter assembly.


b.

Using a T25 "TORX" socket wrench, install the bolt.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)

NOTICE:

Do not touch the waterproof seal of the connector cover assembly.



Hide 821H1 20.DISCONNECT HV FLOOR UNDER WIRE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A376308C02
1.375,0.521 1.865,0.521 true 1.938,0.448 2.25,0.646 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the bolt and disconnect the HV floor under wire from the inverter with converter assembly.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.




b.

Disengage the 2 clamps.


Hide 82311A 21.DISCONNECT AIR CONDITIONING WIRE

CAUTION:

Wear insulated gloves.


a.
A376306C02
1.813,0.594 2.146,0.594 true 2.198,0.542 2.51,0.74 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the 2 bolts and disconnect the air conditioning wire from the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.




b.

Disengage the clamp.


Hide 22.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A376310

Remove the nut and wire harness clamp bracket.


Hide 82123 23.DISCONNECT NO. 3 ENGINE WIRE

CAUTION:

Wear insulated gloves.


a.
A376312

Remove the bolt.


b.
A376313

Remove the bolt.


c.
A376314

Disengage the 2 claws and open the No. 3 engine wire terminal cover.


d.
A376315

Remove the nut.


e.

Disengage the clamp and disconnect the No. 3 engine wire from the inverter with converter assembly.


Hide G922C 24.DISCONNECT OUTLET NO. 1 INVERTER COOLING HOSE

a.
A376316

Slide the clip and disconnect the outlet No. 1 inverter cooling hose from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide G922AA 25.DISCONNECT INLET NO. 1 INVERTER COOLING HOSE

a.
A376318

Slide the clip and disconnect the inlet No. 1 inverter cooling hose from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide G9221 26.REMOVE INVERTER COVER

CAUTION:

Wear insulated gloves.


a.
A376321C02
1.417,2.646 1.719,2.104 1.719,2.104 1.323,2.417 true 1.469,2.823 1.594,3.073 1.594,3.073 1.833,3.073 true 3.052,2.552 3.01,3.083 3.01,3.083 2.781,3.083 false 0.552,2.719 0.604,2.167 0.604,2.167 0.813,2.167 false 1.917,3 2.229,3.198 0.313,0.198 10 false *a 1.771,2.042 2.083,2.24 0.313,0.198 10 false *b 2.667,3.031 2.823,3.229 0.156,0.198 10 false A 0.875,2.115 1.031,2.313 0.156,0.198 10 false A
*a Interlock
*b Waterproof Seal


Remove the 2 bolts and inverter cover from the inverter with converter assembly.

NOTICE:
·

Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.

·

Do not touch the waterproof seal of the inverter cover.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

When removing the inverter cover, do not pull the areas (A) as they may deform.

·

Make sure that the interlock is installed to the inverter cover.

·
A376320C02
2.167,2.115 2.656,1.635 2.656,1.635 2.031,1.24 false 1.031,0.313 1.302,0.313 1.302,0.313 1.823,0.781 true 0.854,0.26 1.167,0.458 0.313,0.198 10 false *a 2.729,1.594 3.042,1.792 0.313,0.198 10 false *1
*1 Inverter Cover
*a Screw


Do not remove or excessively tighten the screw of the inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.



HINT:
A380506

If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.



Hide G1148 27.DISCONNECT MOTOR CABLE

CAUTION:

Wear insulated gloves.


a.
A376322

Using an insulated tool, remove the 6 bolts.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.




b.
A376323C03
0.615,0.208 0.927,0.208 0.927,0.208 1.313,0.563 true 0.427,0.156 0.74,0.354 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·
A380507

To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.




Hide G9200 28.REMOVE INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Wear insulated gloves.


a.

Remove the 5 bolts, 2 nuts and inverter with converter assembly.

A376326

NOTICE:
·

When removing the inverter with converter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.



HINT:

Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.



Hide G9214 29.REMOVE NO. 1 INVERTER BRACKET

a.
A376328C03
2.208,2.031 2.875,1.938 2.875,1.938 2.573,1.854 false 2.938,1.885 3.25,2.083 0.313,0.198 10 false *a
*a Wooden Block


Set the inverter with converter assembly on wooden blocks.

NOTICE:
A380508

Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.



b.

Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.


Hide G9215 30.REMOVE NO. 2 INVERTER BRACKET

a.
A376329C03
2.302,2.052 3.063,1.938 3.063,1.938 2.646,1.854 false 3.115,1.875 3.427,2.073 0.313,0.198 10 false *a
*a Wooden Block


Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.


Hide 31.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A376330

Remove the 2 bolts and 2 wire harness clamp brackets from the inverter with converter assembly.


b.
A376383

Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.


c.
A376331

Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.