The motor generator control ECU, which is built into the inverter with converter assembly, detects pre-boosting high voltage (VL) using the voltage sensor in the boost converter to control boosting. The motor generator control ECU also monitors the boost converter voltage sensor signal line and detects malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0E3116 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold | Boost converter voltage (VL) signal is stuck (Low)
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0E3117 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold | Boost converter voltage (VL) signal is stuck (High)
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0E311F | DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent | Boost converter voltage (VL) signal is stuck (Low) or (High) detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning Light:
Does not come on |
| DTC No. | Data List |
|---|---|
| P0E3116
P0E3117 P0E311F |
VL Voltage |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
Turn the power switch on (READY) and wait for 5 seconds or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| None of the following DTCs are output. | A |
| DTCs of hybrid control system in the tables below are output. | B |
| DTCs of motor generator control system in the tables below are output. | C |
| System | Relevant Diagnosis | |
|---|---|---|
| Hybrid control system | P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open | |
| P312387 | Lost Communication with Missing Message | |
| Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
P0E3116, P0E3117 or P0E311F may be stored due to a malfunction which also causes the DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART