Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
RM3210E _51 Engine / Hybrid System _047524 HYBRID / BATTERY CONTROL _0242208 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0AFC00  Hybrid/EV Battery Sensor Module  P0AFC16  Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold  P0AFC96  Hybrid/EV Battery Sensor Module Component Internal Failure  P308A12  Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery  


DESCRIPTION

If the battery voltage sensor detects an internal malfunction, it sends an error signal to the hybrid vehicle control ECU. When the hybrid vehicle control ECU receives the error signal from the battery voltage sensor, the ECU warns the driver and performs fail-safe control.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0AFC00 Hybrid/EV Battery Sensor Module The hybrid vehicle control ECU receives an error signal from the battery voltage sensor.
(1 trip detection logic)
·

Battery voltage sensor

·

Wire harness or connector


Comes on Master Warning Light:
Comes on
P0AFC16 Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold The hybrid vehicle control ECU receives an error signal from the battery voltage sensor.
(1 trip detection logic)
·

Battery voltage sensor

·

Wire harness or connector


Comes on Master Warning Light:
Comes on
P0AFC96 Hybrid/EV Battery Sensor Module Component Internal Failure The hybrid vehicle control ECU receives an error signal from the battery voltage sensor.
(1 trip detection logic)
·

Battery voltage sensor

·

Wire harness or connector


Comes on Master Warning Light:
Comes on
P308A12 Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery The hybrid vehicle control ECU receives an error signal from the battery voltage sensor.
(1 trip detection logic)
·

Battery voltage sensor

·

Wire harness or connector


Comes on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P0AFC00 Hybrid Battery Sensor Module Power Supply Voltage
P0AFC16
P0AFC96
P308A12

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 10 seconds or more.

7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

A345885E09
0.75,3.802 1.938,4.188 1.188,0.385 10 false Auxiliary Battery 0.604,3 1.354,3.313 0.75,0.313 10 false BATT-MAIN 0.625,1.333 1.417,1.583 0.792,0.25 10 false IGCT-IG 0.354,1.51 0.51,1.708 0.156,0.198 10 false 1 0.365,1.156 0.521,1.354 0.156,0.198 10 false 2 1.802,0.969 2.417,1.167 0.615,0.198 10 false IGCT 1.448,3.115 3.917,3.531 2.469,0.417 10 false Hybrid Vehicle Control ECU 1.917,2.448 2.531,2.646 0.615,0.198 10 false BTH+ 1.917,2.802 2.531,3 0.615,0.198 10 false BTH- 2,2.083 2.458,2.281 0.458,0.198 10 false +B2 2,1.719 2.458,1.917 0.458,0.198 10 false +B1 1.896,1.365 2.51,1.563 0.615,0.198 10 false MREL 3.406,1.177 4.479,1.375 1.073,0.198 10 false PM-IGCT 3.094,1 3.25,1.198 0.156,0.198 10 false 1 3.083,1.302 3.24,1.5 0.156,0.198 10 false 2 4.76,0.219 4.917,0.417 0.156,0.198 10 false 1 5.167,0.219 5.323,0.417 0.156,0.198 10 false 2 4.708,0.49 5.667,0.656 0.958,0.167 10 false IGCT NO. 2 5.833,0.333 6.448,0.531 0.615,0.198 10 false IGCT 5.833,2.458 6.448,2.656 0.615,0.198 10 false BTH+ 5.833,2.813 6.448,3.01 0.615,0.198 10 false BTH- 5.833,3.135 6.292,3.333 0.458,0.198 10 false GND 2.417,2.792 2.875,2.99 0.458,0.198 10 false F2 2.406,2.438 2.865,2.635 0.458,0.198 10 false F2 2.417,2.063 2.875,2.26 0.458,0.198 10 false F3 2.375,1.333 2.833,1.531 0.458,0.198 10 false A50 1.51,0.604 1.677,0.771 0.167,0.167 10 false 2 2.26,0.604 2.427,0.792 0.167,0.188 10 false 1 1.521,0.229 1.677,0.427 0.156,0.198 10 false 3 2.25,0.229 2.406,0.427 0.156,0.198 10 false 5 5.635,0.229 5.792,0.427 0.156,0.198 10 false 1 5.625,2.344 5.865,2.51 0.24,0.167 10 false 2 5.615,2.698 5.771,2.896 0.156,0.198 10 false 3 5.615,3.021 5.771,3.219 0.156,0.198 10 false 5 2.469,1.167 2.615,1.333 0.146,0.167 10 false 5 2.406,1.531 2.885,1.802 0.479,0.271 10 false 11 2.458,1.885 2.615,2.083 0.156,0.198 10 false 1 2.438,2.25 2.75,2.448 0.313,0.198 10 false 41 2.438,2.615 2.75,2.813 0.313,0.198 10 false 42 5.625,3.677 7.125,3.927 1.5,0.25 10 false Battery Voltage Sensor 5.635,3.469 5.948,3.667 0.313,0.198 10 false M35 2.385,1.708 3.167,2.146 0.781,0.438 10 false A50

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (IGCT VOLTAGE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:
·

Check and record any DTCs, INF codes and freeze frame data, then disconnect the cable from the negative (-) auxiliary battery terminal.

·

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




b.

Remove the No. 1 hybrid battery exhaust duct.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
A368051C21
2.167,0.156 2.604,0.385 0.438,0.229 1.948,1.646 2.49,0.958 true 2.771,0.521 2.51,0.885 true 0.104,0.063 0.5,0.375 0.396,0.313 10 false *a 2.26,0.177 2.656,0.49 0.396,0.313 10 false M35 1.75,1.667 2.083,1.927 0.333,0.26 10 false GND 2.844,0.396 3.219,0.719 0.375,0.323 10 false IGCT
*a Component with harness connected
(Battery Voltage Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
M35-1 (IGCT) - M35-5 (GND) Power switch on (IG) 11 to 14 V


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.



f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Install the No. 1 hybrid battery exhaust duct.


Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (BATTERY VOLTAGE SENSOR - BODY GROUND)
2.CHECK HARNESS AND CONNECTOR (BATTERY VOLTAGE SENSOR - BODY GROUND)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery exhaust duct.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL


c.
A368051C22
2.167,0.156 2.604,0.385 0.438,0.229 1.948,1.646 2.49,0.958 true 0.104,0.063 0.5,0.375 0.396,0.313 10 false *a 2.26,0.177 2.656,0.49 0.396,0.313 10 false M35 1.75,1.667 2.083,1.927 0.333,0.26 10 false GND
*a Component with harness connected
(Battery Voltage Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M35-5 (GND) - Body ground Power switch off Below 1 Ω



d.

Install the No. 1 hybrid battery exhaust duct.


Result:
Proceed to
OK
NG



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 2 FUSE - BATTERY VOLTAGE SENSOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY VOLTAGE SENSOR - BODY GROUND)