Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
RM3210E _51 Engine / Hybrid System _047524 HYBRID / BATTERY CONTROL _0242208 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P301100  Hybrid/EV Battery Block 1 Circuit Resistance Out of Range (Extreme)  P30111E  Hybrid/EV Battery Block 1 Circuit Resistance Out of Range  P301200  Hybrid/EV Battery Block 2 Circuit Resistance Out of Range (Extreme)  P30121E  Hybrid/EV Battery Block 2 Circuit Resistance Out of Range  P301300  Hybrid/EV Battery Block 3 Circuit Resistance Out of Range (Extreme)  P30131E  Hybrid/EV Battery Block 3 Circuit Resistance Out of Range  P301400  Hybrid/EV Battery Block 4 Circuit Resistance Out of Range (Extreme)  P30141E  Hybrid/EV Battery Block 4 Circuit Resistance Out of Range  P301500  Hybrid/EV Battery Block 5 Circuit Resistance Out of Range (Extreme)  P30151E  Hybrid/EV Battery Block 5 Circuit Resistance Out of Range  P301600  Hybrid/EV Battery Block 6 Circuit Resistance Out of Range (Extreme)  P30161E  Hybrid/EV Battery Block 6 Circuit Resistance Out of Range  P301700  Hybrid/EV Battery Block 7 Circuit Resistance Out of Range (Extreme)  P30171E  Hybrid/EV Battery Block 7 Circuit Resistance Out of Range  P301800  Hybrid/EV Battery Block 8 Circuit Resistance Out of Range (Extreme)  P30181E  Hybrid/EV Battery Block 8 Circuit Resistance Out of Range  P301900  Hybrid/EV Battery Block 9 Circuit Resistance Out of Range (Extreme)  P30191E  Hybrid/EV Battery Block 9 Circuit Resistance Out of Range  


DESCRIPTION

Refer to the description for DTC P1AC000.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1AC000

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P301100 Hybrid/EV Battery Block 1 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30111E Hybrid/EV Battery Block 1 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301200 Hybrid/EV Battery Block 2 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30121E Hybrid/EV Battery Block 2 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301300 Hybrid/EV Battery Block 3 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30131E Hybrid/EV Battery Block 3 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301400 Hybrid/EV Battery Block 4 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30141E Hybrid/EV Battery Block 4 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301500 Hybrid/EV Battery Block 5 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30151E Hybrid/EV Battery Block 5 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301600 Hybrid/EV Battery Block 6 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30161E Hybrid/EV Battery Block 6 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301700 Hybrid/EV Battery Block 7 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30171E Hybrid/EV Battery Block 7 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301800 Hybrid/EV Battery Block 8 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30181E Hybrid/EV Battery Block 8 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P301900 Hybrid/EV Battery Block 9 Circuit Resistance Out of Range (Extreme) An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P30191E Hybrid/EV Battery Block 9 Circuit Resistance Out of Range An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on

HINT:
·

These DTCs can be stored after clearing DTCs and driving the vehicle for approximately 10 minutes.

·

If internal resistance is abnormal, the voltage of the battery blocks indicated by the DTCs are likely to decrease more than others blocks voltage during acceleration (discharging), and increase more during deceleration (charging).

·

In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "Hybrid Battery Cooling Warning" is displayed on the multi-information display, make sure to perform the following items:

·

Make sure the air intake port is not blocked.

·

Make sure there are no gaps between the connecting parts of the ducts.

·

Clean the No. 1 HV battery intake filter.

Clear the DTCs to reset the learning values even if no DTCs are stored.





Related Data List
DTC No. Data List
P301100
·

Hybrid Battery Block 1 to 9 Voltage *1

·

Internal Resistance 1 to 9


P30111E
P301200
P30121E
P301300
P30131E
P301400
P30141E
P301500
P30151E
P301600
P30161E
P301700
P30171E
P301800
P30181E
P301900
P30191E

HINT:
·

*1: Under normal conditions, the values of Hybrid Battery Block 1, 2, 8 and 9 Voltage will be approximately 16 V and Hybrid Battery Block 3, 4, 5, 6 and 7 Voltage will be approximately 32 V.

·

If there is a short or open in a battery block voltage detection line, the value of Hybrid Battery Block Voltage for the corresponding battery block will be lower than 8 V.

·

The Data List items Internal Resistance 1 to 9 indicate internal resistance correction values used by the hybrid vehicle control ECU to detect malfunctions of the HV battery.



The following items can be helpful when performing repairs:

Data List
·

Ready Signal

·

Vehicle Speed

·

Accelerator Position

·

Shift Position

·

Engine Speed

·

Hybrid Battery Voltage

·

Hybrid Battery Current

·

BATT Voltage

·

Hybrid Battery SOC just after IG-ON

·

Hybrid Battery Maximum SOC

·

Hybrid Battery Minimum SOC

·

Total Distance Traveled

·

Distance from DTC Cleared

·

Engine Run Time


Vehicle Control History Data

Hybrid Battery Voltage Low


CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Drive the vehicle on urban roads for approximately 10 minutes.

HINT:

This DTC may not be stored if the vehicle is stopped or being driven at a constant speed.


7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397

Result:
Result Proceed to
P0AFC00, P0AFC96, P308A12 or P0AFC62 is not output. A
P0AFC00, P0AFC96, P308A12 or P0AFC62 is also output. B


e.

Turn the power switch off.



A

2.CHECK TOTAL DISTANCE DRIVEN

B

2.CHECK TOTAL DISTANCE DRIVEN
a.

Read the odometer to check the total distance the vehicle has been driven.


Result:
Result Proceed to
Total distance driven is less than 200000 km (124280 mile) A
Total distance driven is 200000 km (124280 mile) or more Current total distance driven - total distance driven when hybrid battery terminal block replaced = less than 200000 km (124280 mile) *1
Other than above B


HINT:

*1: If the hybrid battery terminal block has been replaced, use the total distance driven since it was replaced.



A

B

3.REPLACE HV BATTERY
3.REPLACE HV BATTERY

NEXT

REPLACE HYBRID BATTERY TERMINAL BLOCK