P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)
Diagnostic trouble codes · Vehicles built from Aug 2007
DESCRIPTION
Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, SL3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely (Click here).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0778 |
ECM checks for an open or short circuit in shift solenoid valves SL2 (1 trip detection logic) Hybrid IC for solenoid indicates fail |
|
MONITOR DESCRIPTION
The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the circuit (Click here).WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2) |
Disconnect the transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
5 (SL2+) - 12 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
5 (SL2+) - Body ground
Always
10 kΩ or higher
12 (SL2-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector.
Disconnect the ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
B96-12 (SL2+) - B96-13 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
B96-12 (SL2+) - Body ground
Always
10 kΩ or higher
B96-13 (SL2-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SL2 |
![]() ![]() |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
- OK:
- Valve moves and makes operating sound.
|
|
||||
| OK | ||
| ||