P0420 Catalyst System Efficiency Below Threshold (Bank 1)
Diagnostic trouble codes · Vehicles built from Aug 2007
Also covers:
- P0430 Catalyst System Efficiency Below Threshold (Bank 2)
MONITOR DESCRIPTION
The ECM uses the sensors mounted in front of and behind the Three-Way Catalytic Converter (TWC) to monitor its efficiency.The first sensor, the Air-Fuel Ratio (A/F) sensor, sends pre-catalyst information to the ECM. The second sensor, the Heated Oxygen (HO2) sensor, sends post-catalyst information to the ECM.
In order to detect any deterioration in the TWC, the ECM calculates the Oxygen Storage Capacity (OSC) of the TWC. This calculation is based on the voltage output of the HO2 sensor while performing active air- fuel ratio control, rather than the conventional detecting method, which uses the locus ratio.
The OSC value is an indication of the oxygen storage capacity of the TWC. When the vehicle is being driven with a warm engine, active air-fuel ratio control is performed for approximately 15 to 20 seconds. When it is performed, the ECM deliberately sets the air-fuel ratio to lean or rich level. If a rich-lean cycle of the HO2 sensor is long, the OSC becomes greater. There is a direct correlation between the OSCs of the HO2 sensor and the TWC.
The ECM uses the OSC value to determine the state of the TWC. If any deterioration has occurred, it illuminates the MIL and sets a DTC.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0420 |
OSC value is smaller than standard value under active air-fuel ratio control (2 trip detection logic) |
|
| P0430 |
OSC value is smaller than standard value under active air-fuel ratio control (2 trip detection logic) |
|
- HINT:
- Bank 1 refers to the bank that includes cylinder No. 1.
- Bank 2 refers to the bank that does not include cylinder No. 1.
- Sensor 1 refers to the sensor closest to the engine assembly.
- Sensor 2 refers to the sensor farthest away from the engine assembly.
- Bank 1 refers to the bank that includes cylinder No. 1.
CONDITIONING FOR SENSOR TESTING
Perform the operation with the engine speeds and time durations described below prior to checking the waveforms of the A/F and HO2 sensors. This is performed in order to heat the sensors sufficiently to obtain the appropriate inspection results.

- Connect the intelligent tester to the DLC3 (Procedure "A").
- Start the engine and warm it up with all the accessories switched off, until the engine coolant temperature stabilizes (Procedure "B").
- Run the engine at an engine speed of between 2500 rpm and 3000 rpm for at least 3 minutes (Procedure "C").
- While running the engine at 3000 rpm for 2 seconds and 2000 rpm for 2 seconds, check the waveforms of the A/F and HO2 sensors using the tester or scan tool (Procedure "D").
- NOTICE:
- The Air-Fuel Ratio (A/F) sensor has an output delay of a few seconds and the Heated Oxygen (HO2) sensor has a maximum delay of approximately 20 seconds.
| Case |
Air Fuel Ratio Sensor (Sensor 1) Output Voltage |
Heated Oxygen Sensor (Sensor 2) Output Voltage |
Main Suspected Trouble Area |
| 1 |
![]() ![]() |
![]() ![]() |
- |
| 2 |
![]() ![]() |
![]() ![]() |
|
| 3 |
![]() ![]() |
![]() ![]() |
|
| 4 |
![]() ![]() |
![]() ![]() |
|
- Following the Control the Injection Volume for A/F Sensor procedure enables technicians to check and graph the voltage outputs of both the A/F and HO2 sensors.
- The following A/F Control procedure enables the technician to check and graph the voltage output of both the heated oxygen sensors. To display the graph, select the following menu items on the tester: View / Line Graph.
INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction (Click here).
| 1. CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0420 AND/OR P0430) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position and turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read the DTCs.
- Result:
Display (DTC output)
Proceed to
P0420 and/or P0430
A
P0420 and/or P0430 and other DTCs
B
- HINT:
- If any DTCs other than P0420 or P0430 are output, troubleshoot those DTCs first.
|
|
||||
| A | |
| 2. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (A/F CONTROL) |
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester on.
Warm up the engine at a engine speed of 2500 rpm for approximately 90 seconds.
On the tester, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
Perform the Control the Injection Volume for A/F Sensor operation with the engine in an idling condition (press the RIGHT or LEFT button to change the fuel injection volume.)
Monitor the output voltages of the A/F and HO2 sensors (AFS B1 S1 and O2S B1 S2 or AFS B2 S1 and O2S B2 S2) displayed on the tester.
- HINT:
- The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
- Each sensor reacts in accordance with increases and decreases in the fuel injection volume.
- The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
Tester Display
(Sensor)
Injection Volume
Status
Voltage
AFS B1 S1 or AFS B2 S1
(A/F)
+25 %
Rich
Less than 3.0 V
AFS B1 S1 or AFS B2 S1
(A/F)
-12.5 %
Lean
More than 3.35 V
O2S B1 S2 or O2S B2 S2
(HO2)
+25 %
Rich
More than 0.55 V
O2S B1 S2 or O2S B2 S2
(HO2)
-12.5 %
Lean
Less than 0.4 V
- Result:
Status
AFS B1 S1
or
AFS B2 S1
Status
O2S B1 S2
or
O2S B2 S2
A/F Condition and A/F and
HO2 Sensor Condition
Misfire
Main Suspected Trouble Area
Proceed to
Lean/Rich
Lean/Rich
Normal
-
- Three-Way Catalytic Converter (TWC)
- Gas leakage from exhaust system
A
Lean/Lean
Lean/Rich
A/F sensor malfunction
-
- A/F sensor
B
Rich/Rich
Lean/Rich
A/F sensor malfunction
May occur
- A/F sensor
B
Lean/Rich
Lean/Lean
HO2 sensor malfunction
-
- HO2 sensor
- Gas leakage from exhaust system
C
Lean/Rich
Rich/Rich
HO2 sensor malfunction
-
- HO2 sensor
- Gas leakage from exhaust system
C
Lean/Lean
Lean/Lean
Actual air-fuel ratio lean
May occur
- Extremely rich or lean actual air-fuel ratio
- Gas leakage from exhaust system
A
Rich/Rich
Rich/Rich
Actual air-fuel ratio lean
-
- Extremely rich or lean actual air-fuel ratio
- Gas leakage from exhaust system
A
- Three-Way Catalytic Converter (TWC)
- Lean:
- During Control the Injection Volume for A/F Sensor, the A/F sensor (AFS) output voltage is consistently more than 3.35 V, and the HO2 sensor output voltage (O2S) is consistently less than 0.4 V.
- Rich:
- During Control the Injection Volume for A/F Sensor, the AFS is consistently less than 3.0 V, and the O2S is consistently more than 0.55 V.
- Lean/Rich:
- During Control the Injection Volume for A/F Sensor of the Active Test, the output voltage of the HO2 sensor alternates correctly.
|
|
||||
|
|
||||
| A | |
| 3. CHECK FOR EXHAUST GAS LEAK |
- OK:
- No gas leakage.
|
|
||||
| OK | ||
| ||