B1800/51 Short in Driver Side Squib Circuit
Diagnostic trouble codes · Vehicles built Jan 2007 – Jul 2007
Also covers:
- B1801/51 Open in Driver Side Squib Circuit
- B1802/51 Short to GND in Driver Side Squib Circuit
- B1803/51 Short to B+ in Driver Side Squib Circuit
Versions by build date: Nov 2005 – Dec 2006 Jan 2007 – Jul 2007 from Aug 2007
DESCRIPTION
- The driver side squib circuit consists of the center airbag sensor, the spiral cable and the steering pad.
- The circuit instructs the SRS to deploy when the deployment conditions are met.
- These DTCs are recorded when a malfunction is detected in the driver side squib circuit.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1800/51 |
Center airbag sensor receives a line short signal 5 times in the driver side squib circuit during primary check. |
|
| B1801/51 |
Center airbag sensor receives an open signal in the driver side squib circuit for 2 seconds. |
|
| B1802/51 |
Center airbag sensor receives a short to ground signal in the driver side squib circuit for 0.5 seconds. |
|
| B1803/51 |
Center airbag sensor receives a short to B+ signal in the driver side squib circuit for 0.5 seconds. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Perform the simulation method by selecting the "Check Mode" (signal check) with the intelligent tester (Click here).
- After selecting the "Check Mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on a city or rough road (Click here).
- Perform the simulation method by selecting the "Check Mode" (signal check) with the intelligent tester (Click here).
| 1. CHECK STEERING PAD (DRIVER SIDE SQUIB) |
![]() ![]() |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connectors from the steering pad.
Connect the white wire side of SST to connector E.
- CAUTION:
- Never connect a tester to the steering pad (driver side squib) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting.
- Insert SST straight into the terminals of the connector.
- Do not forcibly insert SST into the terminals of the connector when connecting.
- SST
- 09843-18060
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
- OK:
- DTC B1800, B1801, B1802, B1803 or 51 is not output.
- HINT:
- DTCs other than DTC B1800, B1801, B1802, B1803 or 51 may be output at this time, but they are not related to this check.
|
|
||||
| NG | |
| 2. CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from the spiral cable.
Check that the spiral cable connectors (on the steering pad side) are not damaged.
- OK:
- Lock button is not disengaged, and claw of lock is not deformed or damaged.
|
|
||||
| OK | |
| 3. CHECK DRIVER SIDE SQUIB CIRCUIT |
Disconnect the connectors from the center airbag sensor.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
Specified Condition
D+ - Body ground
Below 1 V
D- - Body ground
Below 1 V
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
D+ - D-
Below 1 Ω
D+ - Body ground
1 MΩ or higher
D- - Body ground
1 MΩ or higher
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
D+ - D-
1 MΩ or higher
|
|
||||
| NG | |
| 4. CHECK INSTRUMENT PANEL WIRE |
Restore the released activation prevention mechanism of connector B to its original position.

Disconnect the instrument panel wire connector from the spiral cable.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
Specified Condition
E11-1 (D+) - Body ground
Below 1 V
E11-2 (D-) - Body ground
Below 1 V
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
E11-1 (D+) - E11-2 (D-)
Below 1 Ω
E11-1 (D+) - Body ground
1 MΩ or higher
E11-2 (D-) - Body ground
1 MΩ or higher
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
E11-1 (D+) - E11-2 (D-)
1 MΩ or higher
|
|
||||
| OK | ||
| ||