2005-2008 RAV4 · Service Manual TRANSMISSION

P2769 Torque Converter Clutch Solenoid Circuit Low (Shift Solenoid Valve DSL)

Diagnostic trouble codes · Vehicles built from Aug 2007

Also covers:

DESCRIPTION

The shift solenoid valve DSL is turned ON and OFF by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls operation of the lock-up clutch.
DTC No.
DTC Detection Condition
Trouble Area
P2769
ECM detects short in shift solenoid valve DSL circuit when shift solenoid valve DSL is operated (2 trip detection logic)
  1. Short in shift solenoid valve DSL circuit
  2. Shift solenoid valve DSL
  3. ECM
P2770
ECM detects open in shift solenoid valve DSL circuit when shift solenoid valve DSL is not operated (2 trip detection logic)
  1. Open in shift solenoid valve DSL circuit
  2. Shift solenoid valve DSL
  3. ECM
Fail-safe function:
If the ECM detects a malfunction, it turns the shift solenoid valve DSL OFF.

MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on engine rpm, engine load, engine temperature, vehicle speed, transmission temperature, and shift position selection. The ECM determines the lock-up status of the torque converter by comparing the engine rpm (NE) to the input rpm (NT). The ECM calculates the actual transmission gear by comparing the input rpm (NT) to the output rpm (SP2). When conditions are appropriate, the ECM requests "lock-up" by applying control voltage to the shift solenoid valve DSL. When the shift solenoid valve DSL is opened, the shift solenoid valve DSL applies pressure to the lock-up relay valve and locks the torque converter clutch. If the ECM detects an open or short in the shift solenoid valve DSL circuit, the ECM interprets this as a fault in the shift solenoid valve DSL or its circuit. The ECM will illuminate the MIL and store a DTC.

WIRING DIAGRAM

Refer to DTC P0741 (Click here).

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE DSL)

  1. C136383E37
    Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    10 (DSL) - Body ground
    20°C (68°F)
    11 to 13 Ω



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
  1. Connect the transmission wire connector.

  1. A175191E20
    Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B96-9 (DSL) - Body ground
    20°C (68°F)
    11 to 13 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (for 2GR-FE) (Click here)

3. INSPECT SHIFT SOLENOID VALVE DSL
C113970E14
  1. Remove the shift solenoid valve DSL.

  1. Measure the resistance between the solenoid valve terminal and solenoid valve body.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (DSL) - Solenoid Body (DSL)
    20°C (68°F)
    11 to 13 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating sound.

    OK:
    Valve moves and makes operating sound.



NG
REPLACE SHIFT SOLENOID VALVE DSL (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)


← P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) (from Aug 2007)ON-VEHICLE INSPECTION (from Aug 2007) →