B1421/21 Solar Sensor Circuit (Passenger Side)
Diagnostic trouble codes · Vehicles built from Nov 2005
DESCRIPTION
The solar sensor, which is installed on the upper side of the instrument panel, detects sunlight and controls the air conditioning AUTO mode. The output voltage from the solar sensor varies in accordance with the amount of sunlight. When the sunlight increases, the output voltage increases. As the sunlight decreases, the output voltage decreases.The air conditioning amplifier detects changes in the output voltage from the solar sensor.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1421/21 |
Open or short in passenger side solar sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (SOLAR SENS-P) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Air conditioning amplifier:
Item
Measure Item / Display
(Range)
Normal Condition
Diagnostic Note
Solar Sens-P
Passenger side solar sensor /
Min.: 0, Max.: 255
Passenger side temperature increases as brightness increases
-
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT SOLAR SENSOR |
![]() ![]() |
Remove the solar sensor.
Measure the resistance of the sensor.
Connect the positive (+) lead from the ohmmeter to terminal 1 and the negative (-) lead to terminal 2 of the solar sensor.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 (SS) - 2 (TSP)
Sensor exposed to electric light
Except ∞ Ω
1 (SS) - 2 (TSP)
Sensor covered with cloth
∞ Ω (No continuity)
- NOTICE:
- The connection procedure for using a digital tester such as an electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2 and the negative (-) lead to terminal 1 of the solar sensor.
- HINT:
- As the inspection light is moved away from the sensor, the voltage decreases.
- Use an incandescent light for the inspection. Position it about 30 cm (11.8 in.) from the solar sensor.
- As the inspection light is moved away from the sensor, the voltage decreases.
|
|
||||
| OK | |
| 3. CHECK WIRE HARNESS (SOLAR SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() ![]() |
Disconnect the F1 sensor connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
E41-32 (TSP) - F1-2 (TSP)
Below 1 Ω
E41-31 (S5-4) - F1-1 (SS)
Below 1 Ω
E41-32 (TSP) - Body ground
1 MΩ or higher
E41-31 (S5-4) - Body ground
1 MΩ or higher
|
|
||||
| OK | ||
| ||