B1423/23 Pressure Sensor Circuit
Diagnostic trouble codes · Vehicles built from Nov 2005
DESCRIPTION
This DTC is output when the refrigerant pressure is either extremely low (0.19 MPa [2.0 kgf/cm2, 28 psi] or less) or extremely high (3.14 MPa [32.0 kgf/cm2, 455 psi] or more). The air conditioning pressure sensor, which is installed on the pipe of the high pressure side, detects the refrigerant pressure and sends refrigerant pressure signals to the air conditioning amplifier. The air conditioning amplifier determines the pressure from the signals in accordance with the sensor characteristics, and controls the compressor accordingly.| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1423/23 |
Open or short in air conditioning pressure sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK REFRIGERANT |
![]() ![]() |
Check the sight glass of the cooler unit refrigerant liquid pipe.
Prepare the vehicle in accordance with the chart below.
Item
Condition
Engine Speed
1500 rpm
Vehicle Doors
Fully open
Temperature Setting
MAX COLD
Blower Speed
HI
A/C Switch
ON
Compare the sight glass to the following chart.
Item
Symptom
Amount of Refrigerant
Corrective Procedures
1
Bubbles visible
Insufficient*
- Check for gas leakage and repair if necessary
- Add refrigerant until bubbles disappear
2
No bubbles visible
Empty, insufficient or too much
Refer to items 3 and 4
3
No temperature difference between compressor inlet and outlet
Empty or nearly empty
- Check for gas leakage with gas leak detector and repair if necessary
- Add refrigerant until bubbles disappear
4
Considerable temperature difference between compressor inlet and outlet
Correct or too much
Refer to items 5 and 6
5
Refrigerant becomes clear immediately after A/C turned OFF
Too much
- Drain or discharge refrigerant
- Bleed air and supply proper amount of purified refrigerant
6
Refrigerant foams and then becomes clear immediately after A/C turned OFF
Correct
-
- HINT:
- *: If the ambient temperature is higher than usual but cooling is sufficient, bubbles in the sight glass are permissible.
- Check for gas leakage and repair if necessary
|
|
||||
| OK | |
| 2. READ VALUE USING INTELLIGENT TESTER (REG PRESS SENS) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Air conditioning amplifier:
Item
Measure Item / Display
(Range)
Normal Condition
Diagnostic Note
Reg Press Sens
Regulator pressure sensor /
Min.: 0 MPaG
Max.: 3.187 MPaG
Actual regulator pressure is displayed
-
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 3. CHECK WIRE HARNESS (PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() ![]() |
Disconnect the A32 pressure sensor connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
A32-3 (+) - E41-10 (S5-3)
Below 1 Ω
A32-2 (PR) - E41-9 (PRE)
Below 1 Ω
A32-1 (-) - E41-13 (SG-2)
Below 1 Ω
A32-3 (+) - Body ground
1 MΩ or higher
A32-2 (PR) - Body ground
1 MΩ or higher
A32-1 (-) - Body ground
1 MΩ or higher
|
|
||||
| OK | |
| 4. CHECK AIR CONDITIONING AMPLIFIER |
![]() ![]() |
Remove the air conditioning amplifier with its connectors still connected.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
E41-13 (SG-2) - Body ground
Below 1 Ω
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
Specified Condition
E41-10 (S5-3) - E41-13 (SG-2)
4.5 to 5.5 V
|
|
||||
| OK | |
| 5. INSPECT AIR CONDITIONING PRESSURE SENSOR |
![]() ![]() |
Turn the A/C switch ON.
Disconnect the A32 sensor connector.
Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 3 and the negative (-) lead to terminal 1. Then connect the voltmeter's positive (+) lead to terminal 2 and the negative (-) lead to terminal 1. Measure the voltage.
- OK:
- The voltage changes in accordance with the refrigerant pressure as shown in the graph.
|
|
||||
| OK | ||
| ||




