INSPECTION
Inspection · Vehicles built from Aug 2007
| INSPECT PURGE VSV |
 |
- Measure the resistance of the purge VSV.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 - 2
|
20°C (68°F)
|
23 to 26 Ω
|
1 - Body ground 2 - Body ground
|
Always
|
10 MΩ or higher
|
If the result is not as specified, replace the purge VSV.
Check the operation of the purge VSV.
- Check that air does not flow from port E to port F.
- Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If the result is not as specified, replace the purge VSV.