Entry Functions do not Operate at All
Circuit diagnosis · Vehicles built from Nov 2005
DESCRIPTION
When the entry functions do not operate at all, it is possible that the certification ECU is malfunctioning or that the wire harness leading to the certification ECU is short circuited.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK KEY CANCEL FUNCTION |
Check that the key cancel function has been set (Click here).
- OK:
- Key cancel function is set.
|
|
||||
| NG | |
| 2. CHECK WIRE HARNESS (CERTIFICATION ECU - BATTERY AND BODY GROUND) |
![]() ![]() |
Disconnect the E63 ECU connector.
Measure the resistance and voltage of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
E63-17 (E) - Body ground
Below 1 Ω
- Standard voltage:
Tester Connection
Condition
Specified Condition
E63-18 (IG) - Body ground
Ignition switch on (IG)
10 to 14 V
Ignition switch off
Below 1 V
E63-1 (+B1) - Body ground
Always
10 to 14 V
|
|
||||
| OK | ||
| ||