INSPECTION
Inspection · Vehicles built from Jan 2007
| INSPECT AXIAL PLAY OF TURBINE SHAFT |
Insert the needle of a dial indicator into the exhaust side of the turbine shaft.

Move the turbine shaft in an axial direction and measure the axial play of the turbine shaft using the dial indicator.
If the axial play is greater than the maximum, replace the turbocharger.Maximum axial play
0.08 mm (0.0031 in.)
| INSPECT RADIAL PLAY OF TURBINE SHAFT |
Insert the needle of a dial indicator into the oil outlet hole, and set it in the center of the turbine shaft.

Move the turbine shaft in a radial direction and measure the radial play of the turbine shaft using the dial indicator.
If the radial play is greater than the maximum, replace the turbocharger.Maximum radial play
0.110 mm (0.0043 in.)
| INSPECT ACTUATOR AND WASTE GATE VALVE OPERATION |
Connect the vacuum pump to the actuator.

When creating vacuum in the actuator, check that the actuator linkage moves toward the actuator and that the nozzle vanes move.
- HINT:
- Visually check the movement from where the exhaust manifold and turbocharger are installed.