DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P2716 | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
|

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
![]() |
Remove the TCM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 12 (SLT+) - 7 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 12 (SLT+) - Body ground | Always | 10 kΩ or higher |
| 7 (SLT-) - Body ground | Always | 10 kΩ or higher |
| 12 (SLT+) - All other terminals except 7 (SLT-) | Always | 10 kΩ or higher |
| 7 (SLT-) - All other terminals except 12 (SLT+) | Always | 10 kΩ or higher |
| *1 | Component without TCM connected (Transmission Wire) |
|
| ||||
| OK | ||
| ||
| 2.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| *1 | Component without harness connected (Shift Solenoid Valve SLT) |
|
| ||||
| OK | ||
| ||