DTC B1815/54 Short in Front Passenger Side Squib 2nd Step Circuit |
DTC B1816/54 Open in Front Passenger Side Squib 2nd Step Circuit |
DTC B1817/54 Short to GND in Front Passenger Side Squib 2nd Step Circuit |
DTC B1818/54 Short to B+ in Front Passenger Side Squib 2nd Step Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1815/54 | Center airbag sensor receives a line short signal 5 times in the front passenger side squib 2nd step circuit during primary check. |
|
| B1816/54 | Center airbag sensor receives an open signal in the front passenger side squib 2nd step circuit for 2 seconds. |
|
| B1817/54 | Center airbag sensor receives a short to ground signal in the front passenger side squib 2nd step circuit for 0.5 seconds. |
|
| B1818/54 | Center airbag sensor receives a short to B+ signal in the front passenger side squib 2nd step circuit for 0.5 seconds. |
|

| 1.CHECK FRONT PASSENGER AIRBAG ASSEMBLY (FRONT PASSENGER SIDE SQUIB 2ND STEP) |
![]() |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connector from the front passenger airbag.
Connect SST (resistance 2.1 Ω) to connector E.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from the instrument panel wire.
Check that the instrument panel wire connectors (on the front passenger side airbag) are not damaged.
|
| ||||
| OK | |
| 3.CHECK INSTRUMENT PANEL WIRE |
![]() |
Disconnect the connector from the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| g2-3 (P2+) - Body ground | Below 1 V |
| g2-4 (P2-) - Body ground | Below 1 V |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| g2-2 (P2+) - g2-1 (P2-) | Below 1 Ω |
| g2-2 (P2+) - Body ground | 1 MΩ or higher |
| g2-1 (P2-) - Body ground | 1 MΩ or higher |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| g2-2 (P2+) - g2-1 (P2-) | 1 MΩ or higher |
|
| ||||
| NG | |
| 4.CHECK NO. 2 INSTRUMENT PANEL WIRE |
![]() |
Disconnect the No. 2 instrument panel wire connector from the instrument panel wire.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| g2-2 (P2+) - Body ground | Below 1 V |
| g2-1 (P2-) - Body ground | Below 1 V |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| g2-2 (P2+) - Eg1-3 | Below 1 Ω |
| g2-1 (P2-) - Eg1-4 | Below 1 Ω |
| g2-2 (P2+) - g2-1 (P2-) | Below 1 Ω |
| g2-2 (P2+) - Body ground | 1 MΩ or higher |
| g2-1 (P2-) - Body ground | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||