DTC P0798 Pressure Control Solenoid "C" Electrical (Shift Solenoid Valve SL3) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0798 | An open or short circuit (output signal duty is 0% or 100%) is detected by the TCM in the shift solenoid valve SL3 circuit while driving and shifting gears (SL3 output signal duty is more than 0% and less than 100% under normal conditions) (1-trip detection logic). |
|

| TCM gear shift command | 1st | 2nd | 3rd | 4th | 5th | 6th |
| Shift solenoid valve SL3 | OFF | ON | OFF | OFF | OFF | ON |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL3) |
![]() |
Remove the TCM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 16 (SL3+) - 15 (SL3-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 16 (SL3+) - Body ground | Always | 10 kΩ or higher |
| 15 (SL3-) - Body ground | Always | 10 kΩ or higher |
| 16 (SL3+) - All other terminals except 15 (SL3-) | Always | 10 kΩ or higher |
| 15 (SL3-) - All other terminals except 16 (SL3+) | Always | 10 kΩ or higher |
| *1 | Component without TCM connected (Transmission Wire) |
|
| ||||
| OK | ||
| ||
| 2.INSPECT SHIFT SOLENOID VALVE SL3 |
![]() |
Remove shift solenoid valve SL3.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| *1 | Component without harness connected (Shift Solenoid Valve SL3) |
|
| ||||
| OK | ||
| ||