Home › HEATER & AIR CONDITIONING SYSTEM › HEATER › COMBUSTION TYPE POWER HEATER SYSTEM

COMBUSTION TYPE POWER HEATER SYSTEM > Power Heater Fuel Pump Circuit

for Preparation Click here


DESCRIPTION

When the power heater switch is turned on, the heater pump assembly receives a drive voltage from the heater assembly (ECU). The heater pump assembly provides the heater assembly with fuel necessary for combustion, allowing the heater assembly to operate.

WIRING DIAGRAM


E181362E04


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - HEATER PUMP ASSEMBLY AND BODY GROUND)


    E176772E07
  1. Disconnect the A31 heater connector.

  1. Disconnect the A28 pump connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A31-2 (L) - A28-1
    Always
    Below 1 Ω
    A28-2 - Body ground
    Always
    Below 1 Ω
    A31-2 (L) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Heater Assembly)
    *2
    Front view of wire harness connector
    (to Heater Pump Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.INSPECT HEATER PUMP ASSEMBLY


    E176914
  1. Remove the heater pump assembly with the fuel hose still connected (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Always
    9 to 12 Ω

  1. Apply battery voltage to the heater pump assembly and check the pressure of the hose by hand.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 1
    Battery negative (-) → Terminal 2
    Pressure is applied to the hose

    NOTICE:
    1. This inspection must be done quickly (within 10 seconds) to prevent damage to the heater pump assembly.
    2. Always switch the voltage on and off on the battery side, not the heater pump assembly side.
    3. Keep the heater pump assembly as far away from the battery as possible.



NG
REPLACE HEATER PUMP ASSEMBLY (Click here)
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)