DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |
DTC P0057 Oxygen Sensor Heater Control Circuit Low (Bank 2 Sensor 2) |
DTC P0058 Oxygen Sensor Heater Control Circuit High (Bank 2 Sensor 2) |


| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 P0057 | Heated Oxygen (HO2) sensor heater current is less than 0.3 A (1 trip detection logic) |
|
| P0038 P0058 | Heated Oxygen (HO2) sensor heater current is more than 3.5 A (1 trip detection logic) |
|
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
![]() |
Disconnect the heated oxygen sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| HT1B (1) - +B (2) | 20°C (68°F) | 11 to 16 Ω |
| HT1B (1) - E2 (4) | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| HT2B (1) - +B (2) | 20°C (68°F) | 11 to 16 Ω |
| HT2B (1) - E2 (4) | Always | 10 kΩ or higher |
Reconnect the HO2 sensor connector.
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (+B OF HO2 SENSOR) |
![]() |
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to the ON position.
Measure the voltage between the terminals.
| Tester Connection | Specified Condition |
| +B (2) - Body ground | 9 to 14 V |
Reconnect the HO2 sensor connector.
|
| ||||
| NG | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (HO2 SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Terminal Connection | Specified Condition |
| HT1B (E94-1) - HT1B (B96-48) | Below 1 Ω |
| OX1B (E94-3) - OX1B (B96-88) | Below 1 Ω |
| E2 (E94-4) - EX1B (B96-65) | Below 1 Ω |
| Terminal Connection | Specified Condition |
| HT2B (B95-1) - HT2B (B96-47) | Below 1 Ω |
| OX2B (B95-3) - OX2B (B96-87) | Below 1 Ω |
| E2 (B95-4) - EX2B (B96-64) | Below 1 Ω |
| Terminal Connection | Specified Condition |
| HT1B (E94-1) or HT1B (B96-48) - Body ground | 10 kΩ or higher |
| OX1B (E94-3) or OX1B (B96-88) - Body ground | 10 kΩ or higher |
| E2 (E94-4) or EX1B (B96-65) - Body ground | 10 kΩ or higher |
| Terminal Connection | Specified Condition |
| HT2B (B95-1) or HT2B (B96-47) - Body ground | 10 kΩ or higher |
| OX2B (B95-3) or OX2B (B96-87) - Body ground | 10 kΩ or higher |
| E2 (B95-4) or EX2B (B96-64) - Body ground | 10 kΩ or higher |
Reconnect the HO2 sensor connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 4.CHECK WHETHER DTC OUTPUT RECURS |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the intelligent tester on.
Clear the DTCs (Click here).
Start the engine.
Allow the engine to idle for 2 minutes.
Select the following menu items: Powertrain / Engine and ECT / DTC.
Read the DTCs.
| Display (DTC Output) | Proceed to |
| No output | A |
| P0037, P0038, P0057 and/or P0058 | B |
|
| ||||