DTC P0351 Ignition Coil "A" Primary / Secondary Circuit |
DTC P0352 Ignition Coil "B" Primary / Secondary Circuit |
DTC P0353 Ignition Coil "C" Primary / Secondary Circuit |
DTC P0354 Ignition Coil "D" Primary / Secondary Circuit |
DTC P0355 Ignition Coil "E" Primary / Secondary Circuit |
DTC P0356 Ignition Coil "F" Primary / Secondary Circuit |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0351 P0352 P0353 P0354 P0355 P0356 | No IGF signal to ECM while engine is running (1 trip detection logic) |
|
![]() |
| Item | Content |
| Terminal | CH1: IGT1, IGT2, IGT3, IGT4, IGT5, IGT6 - E1 CH2: IGF1 - E1 |
| Equipment Setting | 2 V/DIV. 20 ms./DIV. |
| Condition | Cranking or idling |


| 1.INSPECT IGNITION COIL ASSEMBLY (POWER SOURCE) |
![]() |
Disconnect the ignition coil connector.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| +B (B90-1) - Body ground | 9 to 14 V |
| +B (B76-1) - Body ground | 9 to 14 V |
| +B (B89-1) - Body ground | 9 to 14 V |
| +B (B75-1) - Body ground | 9 to 14 V |
| +B (B83-1) - Body ground | 9 to 14 V |
| +B (B73-1) - Body ground | 9 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| GND (B90-4) - Body ground | Below 1 Ω |
| GND (B76-4) - Body ground | Below 1 Ω |
| GND (B89-4) - Body ground | Below 1 Ω |
| GND (B75-4) - Body ground | Below 1 Ω |
| GND (B83-4) - Body ground | Below 1 Ω |
| GND (B73-4) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM (IGT SIGNAL TERMINAL)) |
Disconnect the ignition coil connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| IGT1 (B90-3) - IGT1 (B96-40) | Below 1 Ω |
| IGT2 (B76-3) - IGT2 (B96-39) | Below 1 Ω |
| IGT3 (B89-3) - IGT3 (B96-38) | Below 1 Ω |
| IGT4 (B75-3) - IGT4 (B96-37) | Below 1 Ω |
| IGT5 (B83-3) - IGT5 (B96-36) | Below 1 Ω |
| IGT6 (B73-3) - IGT6 (B96-35) | Below 1 Ω |
| IGF (B90-2) - IGF1 (B96-106) | Below 1 Ω |
| IGF (B76-2) - IGF1 (B96-106) | Below 1 Ω |
| IGF (B89-2) - IGF1 (B96-106) | Below 1 Ω |
| IGF (B75-2) - IGF1 (B96-106) | Below 1 Ω |
| IGF (B83-2) - IGF1 (B96-106) | Below 1 Ω |
| IGF (B73-2) - IGF1 (B96-106) | Below 1 Ω |
| Tester Connection | Specified Condition |
| IGT1 (B90-3) or IGT1 (B96-40) - Body ground | 10 kΩ or higher |
| IGT2 (B76-3) or IGT2 (B96-39) - Body ground | 10 kΩ or higher |
| IGT3 (B89-3) or IGT3 (B96-38) - Body ground | 10 kΩ or higher |
| IGT4 (B75-3) or IGT4 (B96-37) - Body ground | 10 kΩ or higher |
| IGT5 (B83-3) or IGT5 (B96-36) - Body ground | 10 kΩ or higher |
| IGT6 (B73-3) or IGT6 (B96-35) - Body ground | 10 kΩ or higher |
| IGF (B90-2) or IGF1 (B96-106) - Body ground | 10 kΩ or higher |
| IGF (B76-2) or IGF1 (B96-106) - Body ground | 10 kΩ or higher |
| IGF (B89-2) or IGF1 (B96-106)- Body ground | 10 kΩ or higher |
| IGF (B75-2) or IGF1 (B96-106) - Body ground | 10 kΩ or higher |
| IGF (B83-2) or IGF1 (B96-106) - Body ground | 10 kΩ or higher |
| IGF (B73-2) or IGF1 (B96-106) - Body ground | 10 kΩ or higher |
Reconnect the ignition coil connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 3.PERFORM SIMULATION TEST |
Clear the DTC(s) (Click here).
Change the arrangement of the ignition coils (with igniters).
Perform a simulation test.
| Display (DTC Output) | Proceed to |
| Same DTCs (that have been erased) | A |
| Other DTCs | B |
|
| ||||
| A | ||
| ||