Home › ENGINE · 2GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0516    Battery Temperature Sensor Circuit Low

DTC    P0517    Battery Temperature Sensor Circuit High

for Preparation Click here


DESCRIPTION

A110648E01
The battery temperature sensor installed on the battery current sensor detects battery temperature.
A thermistor is integrated into the battery temperature sensor, and the resistance in the battery temperature sensor changes according to the battery temperature.
The resistance of the thermistor in the battery temperature sensor decreases as the battery temperature increases. The resistance increases as the temperature decreases.
The battery temperature sensor is connected to the ECM. The ECM supplies 5 V from the THB terminal to the battery temperature sensor through resistor R.
The battery temperature sensor and resistor R are connected in series. This results in fluctuations in the voltage supplied from the THB terminal when the resistance changes according to the battery temperature.
The ECM determines the battery temperature according to fluctuations in voltage. When the battery temperature is high, the ECM determines to reduce the amount of current supplied from the generator in order to protect the battery.

DTC No.
DTC Detection Condition
Trouble Area
P0516
Battery temperature sensor output value is 0.2 V or less for 0.5 seconds or more with the ignition switch to the ON position
(1 trip detection logic)
  1. Battery temperature sensor
  2. Short in battery temperature sensor circuit
  3. ECM
P0517
Battery temperature sensor output value is 4.8 V or more for 0.5 seconds or more with the ignition switch to the ON position
(1 trip detection logic)
  1. Battery temperature sensor
  2. Open in battery temperature sensor circuit
  3. ECM

WIRING DIAGRAM

Refer to DTC P1550 (Click here).

INSPECTION PROCEDURE

1.INSPECT BATTERY CURRENT SENSOR ASSEMBLY


    A124656E07
  1. Disconnect the battery current sensor connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    THB (1) - E2 (4)
    24 to 26°C (75 to 79°F)
    1.91 to 2.065 kΩ



NG
REPLACE BATTERY CURRENT SENSOR
OK


2.CHECK HARNESS AND CONNECTOR (BATTERY CURRENT SENSOR - ECM)


    A127962E19
  1. Disconnect the battery current sensor connector.

  1. Disconnect the ECM connectors.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    THB (B31-1) - THB (B96-103)
    Below 1 Ω
    E2 (B31-4) - EIB (B96-101)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    THB (B31-1) or THB (B96-103) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)