DTC B1900/73 Short in Front Driver Side Pretensioner Squib Circuit |
DTC B1901/73 Open in Front Driver Side Pretensioner Squib Circuit |
DTC B1902/73 Short to GND in Front Driver Side Pretensioner Squib Circuit |
DTC B1903/73 Short to B+ in Front Driver Side Pretensioner Squib Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1900/73 | Center airbag sensor receives a line short signal 5 times in the driver side front pretensioner squib circuit during primary check. |
|
| B1901/73 | Center airbag sensor receives an open signal in the driver side front pretensioner squib circuit for 2 seconds. |
|
| B1902/73 | Center airbag sensor receives a short to ground signal in the driver side front pretensioner squib circuit for 0.5 seconds. |
|
| B1903/73 | Center airbag sensor receives a short circuit to B+ signal in the driver side front pretensioner squib circuit for 0.5 seconds. |
|

| 1.CHECK DRIVER SIDE FRONT SEAT OUTER BELT ASSEMBLY (DRIVER SIDE FRONT PRETENSIONER SQUIB) |
![]() |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connectors from the driver side front seat outer belt.
Connect SST (resistance 2.1 Ω) to connector C.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the floor wire connector (on the driver side front seat outer belt) is not damaged.
|
| ||||
| OK | |
| 3.CHECK FLOOR WIRE (DRIVER SIDE FRONT PRETENSIONER SQUIB CIRCUIT) |
![]() |
Disconnect the connector from the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| K9-1 (L+) - Body ground | Below 1 V |
| K9-2 (L-) - Body ground | Below 1 V |
| Tester Connection | Specified Condition |
| L5-1 (R+) - Body ground | Below 1 V |
| L5-2 (R-) - Body ground | Below 1 V |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| K9-1 (L+) - K9-2 (L-) | Below 1 Ω |
| K9-1 (L+) - Body ground | 1 MΩ or higher |
| K9-2 (L-) - Body ground | 1 MΩ or higher |
| Tester Connection | Specified Condition |
| L5-1 (R+) - L5-2 (R-) | Below 1 Ω |
| L5-1 (R+) - Body ground | 1 MΩ or higher |
| L5-2 (R-) - Body ground | 1 MΩ or higher |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| K9-1 (L+) - K9-2 (L-) | 1 MΩ or higher |
| Tester Connection | Specified Condition |
| L5-1 (R+) - L5-2 (R-) | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||