SFI SYSTEM > Starter Signal Circuit |


| 1.READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Read the value displayed on the tester when the ignition switch is ON and when the engine is cranking.
| Ignition Switch Position | Starter Signal |
| ON | OFF |
| START | ON |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (ECM - ST RELAY) |
![]() |
Remove the ST relay from the No. 7 relay block (for LHD).
Remove the ST relay from the No. 8 relay block (for RHD).
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| ST relay terminal 1 - A12-48 (STA) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| ST relay terminal 1 or A12-48 (STA) - Body ground | Always | 10 kΩ or higher |
Reinstall the ST relay.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||