DTC P104A Valvematic SDOWN Circuit Malfunction |
| DTC No. | DTC Detection Condition | Trouble Area |
| P104A | The shutdown (SDOWN) signal line has an open circuit, or a short circuit to +B or ground (1 trip detection logic).
|
|

| Actuator position learning is performed when these DTCs are stored. |
| P1046, P1049, P104A, P1055, P2646, P2647, P2648, P2649, P264A, U011B |
| 1.CHECK ANY OTHER DTCS OUTPUT |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read the DTC.
| Result | Proceed to |
| DTC P104A is output | A |
| DTC P1049 is output at same time as DTC P104A | B |
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (CONTINUOUSLY VARIABLE VALVE LIFT CONTROLLER - ECM) |
![]() |
Disconnect the continuously variable valve lift controller assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A12-37 (SDWN) - B127-3 (SDWN) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A12-37 (SDWN) or B127-3 (SDWN) - Body ground | Ignition switch off | 10 kΩ or higher |
| *1 | Front view of wire harness connector (to Continuously Variable Valve Lift Controller) |
| *2 | Front view of wire harness connector (to ECM) |
|
| ||||
| OK | ||
| ||