DESCRIPTION
When the 4WD ECU assembly is replaced with a normal one from another vehicle or the acceleration sensor (airbag sensor assembly) is replaced, perform calibration.
Follow the chart to perform calibration.
When the 4WD ECU assembly is replaced with a new one, calibration is unnecessary.
PERFORM CALIBRATION (When Using Techstream)
Clear the zero point calibration data.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Chassis / Four Wheel Drive / Utility / Reset Memory.
| Tester Display |
|---|
| Reset Memory |
Operate the Techstream to clear the data.
PERFORM CALIBRATION (When Using SST Check Wire)
Calibrate the 4WD ECU assembly by performing vehicle stability control system calibration.