PROCEDURE

Hide 1.INSTALL NO. 3 ULTRASONIC SENSOR

a.

Attach the 4 claws to install the No. 3 ultrasonic sensor as shown in the illustration.

E266773

NOTICE:
·
E270085
1.969,1.573 2.24,0.24 2.24,0.24 2.719,0.24 false 1.823,2.219 2.083,3.146 2.083,3.146 2.583,3.146 false 2.635,3.052 2.948,3.208 0.313,0.156 10 *a 2.833,0.115 3.146,0.271 0.313,0.156 10 *b
*a No. 3 ultrasonic sensor direction
*b Keyhole direction


The No. 3 ultrasonic sensor direction is the same as the keyhole direction.

·

Do not damage the bumper when inserting the No. 3 ultrasonic sensor.




Hide 2.INSTALL NO. 2 LUGGAGE ROOM WIRE

NOTICE:
·

When connecting the wire harness to the No. 3 ultrasonic sensor, hold the sensor from bumper surface.

·

After connecting the wire harness to the No. 3 ultrasonic sensor, push the sensor from the bumper surface.



a.

Attach the 6 clamps to install the No. 2 luggage room wire.


b.

Connect the 4 connectors.