Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)
RM30B0U _59 Vehicle Exterior _010076 WINDOW / GLASS _0058468 POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function) D

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)  INITIALIZATION  


INITIALIZE POWER WINDOW CONTROL SYSTEM (FOR DRIVER DOOR)


NOTICE:
·

When the front power window regulator motor assembly LH, front door window regulator sub-assembly LH, door glass or door glass run is reinstalled or replaced, the power window control system must be initialized. Functions such as the auto up and down, jam protection and key-off operation will not operate if initialization is not performed.

·

When the front power window regulator motor assembly LH is replaced, DTC B2313 is stored. Clear the DTC after initialization.

·

When performing initialization, do not perform any other procedures.

·

If initialization does not complete properly, the LIN communication system may be malfunctioning.

Click herePower Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

·

Make sure to park the vehicle and turn off all electrical systems before performing initialization. Initialization will be canceled if the vehicle is driven during initialization.

·

Make sure not to hit, strike or vibrate the door window glass during initialization because the vehicle is learning the sliding resistance of the door window glass.

·

Make sure not to turn the ignition switch to ON or off during initialization.



HINT:

If the battery has been replaced, it is not necessary to initialize the front power window regulator motor assembly LH.


a.

Perform initialization according to the table below.

Condition of Power Window Proceed to
Initialization method when the front power window regulator motor assembly LH has been replaced with a new one. Procedure A
Initialization method when the front power window regulator motor assembly LH has been removed/installed or a front door window regulator sub-assembly or door glass and/or door glass run etc. have been removed/installed or replaced with new ones.
HINT:

Use this procedure if the front power window regulator motor assembly LH is being reused.


Procedure B
Initialization method when a reverse rotation malfunction occurs due to a sliding resistance change resulting from adjustment etc. Procedure C


b.

Procedure A

i.

Connect the battery and turn the ignition switch to ON.


ii.

Fully open the power window by fully pushing down the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully opened.


iii.

Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.



c.

Procedure B

i.

Connect the battery and turn the ignition switch to ON.


ii.

Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway, even when the switch is fully pulled up, release the switch and fully pull it up again).


iii.

Fully open the power window by fully pushing down the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully opened.


iv.

Release the power window regulator master switch assembly. Then fully push down and hold the switch for 4 seconds or more.


v.

Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.



d.

Procedure C

i.

Connect the battery and turn the ignition switch to ON.


ii.

Fully open the power window by fully pushing down the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully opened.


iii.