U660F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0712  Transmission Fluid Temperature Sensor "A" Circuit Low Input  P0713  Transmission Fluid Temperature Sensor "A" Circuit High Input  


DESCRIPTION

Refer to DTC P0711.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P0711

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input ATF temperature sensor resistance is below 79 Ω for 0.5 sec. or more (1-trip detection logic).
·

Short in ATF temperature sensor circuit

·

Transmission wire

·

ATF temperature sensor (ATF temperature sensor assembly)

·

TCM


Comes on DTC stored
P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input ATF temperature sensor resistance is higher than 156 kΩ for 0.5 sec. or more when 15 minutes or more have elapsed after the engine starts (1-trip detection logic).
·

Open in ATF temperature sensor circuit

·

Transmission wire

·

ATF temperature sensor (ATF temperature sensor assembly)

·

TCM


Comes on DTC stored

MONITOR DESCRIPTION

These DTCs indicate an open or short in the ATF temperature sensor circuit. The ATF temperature sensor converts ATF temperature into an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and the TCM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is below 79 Ω*1 or higher than 156 kΩ*2, the TCM interprets this as a fault in the ATF sensor or wiring. The TCM will turn on the MIL and store the DTC.

HINT:
·

The ATF temperature can be checked on the GTS display.

·

*1: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.

·

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.



WIRING DIAGRAM

C279361
5.604,2.854 5.917,3.052 0.313,0.198 10 E2 5.604,2.083 6.26,2.281 0.656,0.198 10 THO1 5.604,1.427 6.365,1.615 0.76,0.188 10 TPS3 5.344,1.531 5.656,1.729 0.313,0.198 10 19 5.344,2.188 5.656,2.385 0.313,0.198 10 18 5.333,2.969 5.646,3.167 0.313,0.198 10 17 2.208,3.885 4.458,4.104 2.25,0.219 10 Automatic Transaxle Assembly 1.042,3.333 3.427,3.552 2.385,0.219 10 ATF Temperature Sensor Assembly 3.76,3.333 5.167,3.552 1.406,0.219 10 Transmission Wire 1.563,2.479 3.313,2.677 1.75,0.198 10 ATF Temperature Sensor 1.49,1.75 3.458,1.958 1.969,0.208 10 No. 3 ATF Pressure Switch 5.823,4.021 6.479,4.219 0.656,0.198 10 TCM

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION


DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / ECT / Data List.


g.

According to the display on the GTS, read the Data List.

Powertrain > ECT > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
A/T Oil Temperature 1 ATF temperature sensor value Min.: -40°C (-40°F)
Max.: 215°C (419°F)
·

After stall test: Approx. 80°C (176°F)

·

Equal to ambient temperature after cold soak


If the value is "-40°C (-40°F)" or "150°C (302°F)", the ATF temperature sensor circuit is open or shorted.
Powertrain > ECT > Data List
Tester Display
A/T Oil Temperature 1
50003 64 177
HINT:

When DTC P0712 is output and the GTS indicates 150°C (302°F) or more, there is a short circuit.

When DTC P0713 is output and the GTS indicates -40°C (-40°F), there is an open circuit.

Check the temperature displayed on the GTS in order to check if a malfunction exists.


Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or more Short circuit

If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately stored (in 0.5 seconds). When P0713 is stored, P0711 cannot be stored.

It is not necessary to inspect the circuit when P0711 is stored.



PROCEDURE

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)
a.
C207057
1.729,1.5 1.885,1.135 true 2.208,1.5 2,1.135 true 1.521,1.531 1.948,1.729 0.427,0.198 10 THO1 2.167,1.542 2.417,1.74 0.25,0.198 10 E2 0.427,0.292 0.74,0.49 0.313,0.198 10 *a
*a Component without TCM connected
(Transmission Wire)


Remove the TCM.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
18 (THO1) - 17 (E2) Always 79 Ω to 156 kΩ
18 (THO1) - Body ground Always 10 kΩ or higher
17 (E2) - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.



Resistance (Reference):
ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ


Result:
Proceed to
OK
NG



OK

NG

2.INSPECT ATF TEMPERATURE SENSOR
2.INSPECT ATF TEMPERATURE SENSOR
a.
C206308
2.26,1.438 2.042,1.063 true 1.688,1.438 1.875,1.063 true 1.563,1.479 1.802,1.677 0.24,0.198 10 E2 2.115,1.479 2.542,1.677 0.427,0.198 10 THO1 0.677,0.427 0.99,0.625 0.313,0.198 10 *a
*a Component without TCM connected
(ATF Temperature Sensor Assembly)


Disconnect the ATF temperature sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
THO1 - E2 Always 79 Ω to 156 kΩ
THO1 - Body ground Always 10 kΩ or higher
E2 - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.



Resistance (Reference):
ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ


Result:
Proceed to
OK
NG



OK

NG

REPLACE ATF TEMPERATURE SENSOR (ATF TEMPERATURE SENSOR ASSEMBLY)