Home › Drivetrain › U660F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM
RM3090E _52 Drivetrain _008436 U660F AUTOMATIC TRANSMISSION / TRANSAXLE _0047080 AUTOMATIC TRANSAXLE SYSTEM C

U660F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0798  Pressure Control Solenoid "C" Electrical (Shift Solenoid Valve SL3)  


DESCRIPTION

Changing from 1st to 6th is performed by the TCM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0798 Pressure Control Solenoid "C" Electrical (Shift Solenoid Valve SL3) An open or short circuit (output signal duty is 0% or 100%) is detected by the TCM in the shift solenoid valve SL3 circuit while driving and shifting gears (SL3 output signal duty is more than 0% and less than 100% under normal conditions) (1-trip detection logic).
·

Open or short in shift solenoid valve SL3 circuit

·

Shift solenoid valve SL3

·

TCM


Comes on DTC stored

MONITOR DESCRIPTION

The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem and illuminates the MIL and stores the DTC. And the TCM performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART

WIRING DIAGRAM

C279421
2.302,3.042 4.51,3.26 2.208,0.219 10 false Automatic Transaxle Assembly 1.042,2.5 3.406,2.74 2.365,0.24 10 false Transmission Valve Body Assembly 3.771,2.5 5.156,2.729 1.385,0.229 10 false Transmission Wire 5.604,1.25 6.167,1.448 0.563,0.198 10 false SL3+ 5.604,2.021 6.042,2.219 0.438,0.198 10 false SL3- 5.333,1.354 5.667,1.563 0.333,0.208 10 false 16 5.333,2.135 5.667,2.344 0.333,0.208 10 false 15 5.802,3.188 6.24,3.385 0.438,0.198 10 false TCM 1.563,1.646 5.229,1.844 3.667,0.198 10 false Shift Solenoid Valve SL3 1.135,1.229 1.469,1.438 0.333,0.208 10 false 1 1.135,2.042 1.469,2.25 0.333,0.208 10 false 2

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION


HINT:

The following table shows normal operation of shift solenoid valve SL3 when the shift lever is in D:

TCM gear shift command 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SL3 OFF ON OFF OFF OFF ON


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL3)
a.
C207057
1.177,1.49 1.427,0.948 true 1.802,1.51 1.542,0.948 true 0.604,0.229 0.917,0.427 0.313,0.198 10 *a 1.021,1.552 1.448,1.75 0.427,0.198 10 SL3+ 1.688,1.552 2.115,1.75 0.427,0.198 10 SL3-
*a Component without TCM connected
(Transmission Wire)


Remove the TCM.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
16 (SL3+) - 15 (SL3-) 20°C (68°F) 5.0 to 5.6 Ω
16 (SL3+) - Body ground Always 10 kΩ or higher
15 (SL3-) - Body ground Always 10 kΩ or higher
16 (SL3+) - All other terminals except 15 (SL3-) Always 10 kΩ or higher
15 (SL3-) - All other terminals except 16 (SL3+) Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

2.INSPECT SHIFT SOLENOID VALVE SL3
2.INSPECT SHIFT SOLENOID VALVE SL3
a.
C197715C16
1.75,1 2.208,0.365 false 1.49,1 1.052,0.365 false 1.76,2.948 2.208,2.354 false 1.51,2.948 1.052,2.354 false 0.135,0.208 0.448,0.406 0.313,0.198 10 *1 2.25,0.25 2.417,0.448 0.167,0.198 10 1 0.917,0.25 1.083,0.448 0.167,0.198 10 2 2.25,2.25 2.417,2.448 0.167,0.198 10 1 0.917,2.25 1.083,2.448 0.167,0.198 10 2 1.927,3.927 2.156,4.125 0.229,0.198 10 (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 (-)
*1 Shift Solenoid Valve SL3


Remove shift solenoid valve SL3.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

NG