Home › Power Source / Network › 3ZR-FAE BATTERY / CHARGING › BATTERY CURRENT SENSOR › 2012.12–2015.04
RM3090E _57 Power Source / Network _008394 3ZR-FAE BATTERY / CHARGING _0049599 BATTERY CURRENT SENSOR A

3ZR-FAE BATTERY / CHARGING  BATTERY CURRENT SENSOR  INSTALLATION  


PROCEDURE

Hide 28850 1.INSTALL GENERATOR CONTROL ECU ASSEMBLY (BATTERY CURRENT SENSOR)

a.

Install the negative (-) battery terminal to the battery and tighten the nut.

Torque:
5.4 N*m (55 kgf*cm, 48 in.*lbf)


b.
A297358N01
0.75,0.313 0.906,0.51 0.156,0.198 10 A 2.125,0.406 2.281,0.604 0.156,0.198 10 B

Connect the generator control ECU assembly to the negative (-) battery terminal with the nut A.

Torque:
7.6 N*m (77 kgf*cm, 67 in.*lbf)


c.

Connect the No. 3 engine wire to the generator control ECU assembly with nut B.

Torque:
7.6 N*m (77 kgf*cm, 67 in.*lbf)


d.

Connect the connector to the generator control ECU assembly.

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION