Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) › 2012.12–2015.10
RM3090E _58 Vehicle Interior _008789 HEATING / AIR CONDITIONING _0049189 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  B1423  Pressure Sensor Circuit  


DESCRIPTION

This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa [1.8 kgf/cm2, 26 psi] or less) or extremely high (3025 kPa [30.8 kgf/cm2, 439 psi] or more). The air conditioner pressure sensor, which is installed on the pipe on the high pressure side to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1423 Pressure Sensor Circuit
·

Open or short in air conditioner pressure sensor circuit

·

Refrigerant pressure on high pressure side is extremely low (176 kPa [1.8 kgf/cm2, 26 psi] or less) or extremely high (3025 kPa [30.8 kgf/cm2, 439 psi] or more)


·

Air conditioner pressure sensor

·

Harness or connector

·

Air conditioning amplifier assembly

·

Cooler expansion valve (blocked, stuck)

·

Condenser assembly (blocked, deterioration of cooling capacity due to dirt)

·

Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)

·

Cooling fan system (condenser assembly cannot be cooled down)

·

Air conditioning system (leaks, blocked)


-

WIRING DIAGRAM

E229252E34
2.198,1.969 2.292,2.146 0.094,0.177 10 1 2.198,1.021 2.292,1.198 0.094,0.177 10 2 4.854,1.021 4.948,1.198 0.094,0.177 10 7 4.854,1.969 5.031,2.146 0.177,0.177 10 5 1.885,1.115 2.583,1.688 0.698,0.573 10 PR 1.042,3.938 2.552,4.344 1.51,0.406 10 Air Conditioner Pressure Sensor 1.042,3.792 1.323,3.969 0.281,0.177 10 A34 5.052,2.083 5.396,2.26 0.344,0.177 10 SG-2 5.052,3.042 5.396,3.219 0.344,0.177 10 S5-3 4.677,3.781 4.969,3.958 0.292,0.177 10 G80 4.688,3.938 6.229,4.406 1.542,0.469 10 Air Conditioning Amplifier Assembly 2.198,2.927 2.292,3.104 0.094,0.177 10 3 2,2.052 2.094,2.229 0.094,0.177 10 - 2,3.021 2.104,3.198 0.104,0.177 10 + 4.792,2.927 4.969,3.104 0.177,0.177 10 24 5.052,1.146 5.385,1.323 0.333,0.177 10 PRE

CAUTION / NOTICE / HINT

HINT:

If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B1423 first.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.
E269924C01
1.51,0.323 1.927,0.594 0.417,0.271 2.01,1.25 2.26,1.594 2.26,1.594 2.458,1.594 true 1.594,0.385 1.885,0.573 0.292,0.188 10 A34 2.521,1.521 2.979,1.719 0.458,0.198 10 + 0.042,0.042 0.5,0.24 0.458,0.198 10 *a
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)


Disconnect the air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A34-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)

NG

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
a.
E269924C02
1.521,0.323 1.927,0.552 0.406,0.229 0.635,1.542 1.031,1.542 1.031,1.542 1.438,1.271 true 0.042,0.052 0.354,0.25 0.313,0.198 10 *a 1.604,0.354 1.917,0.552 0.313,0.198 10 A34 0.469,1.458 0.781,1.656 0.313,0.198 10 -
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)


Disconnect the air conditioner pressure sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-1 (-) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.
E220539C16
1.49,0.229 1.833,0.49 0.344,0.26 0.667,1.677 1.219,1.177 false 0.198,0.135 0.552,0.365 0.354,0.229 10 *a 1.542,0.26 2.052,0.531 0.51,0.271 10 G80 0.427,1.719 0.813,1.917 0.385,0.198 10 PRE
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Remove the air conditioning amplifier assembly with the connector still connected.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
G80-7 (PRE) - Body ground Ignition switch ON
A/C switch off
0.74 to 4.62 V


HINT:

If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.



Result:
Proceed to
OK
NG



OK

4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Measure the voltage when the following conditions are satisfied.

Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.
E220539C19
1.49,0.229 1.833,0.49 0.344,0.26 0.667,1.677 1.219,1.177 false 0.198,0.135 0.552,0.365 0.354,0.229 10 *a 1.542,0.26 2.052,0.531 0.51,0.271 10 G80 0.427,1.719 0.813,1.917 0.385,0.198 10 PRE
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
G80-7 (PRE) - Body ground Ignition switch ON
A/C switch on
0.74 to 4.62 V




Result:
Result Proceed to
OK (When troubleshooting according to the DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C



A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C

13.INSPECT COOLING FAN SYSTEM
5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the G80 air conditioning amplifier assembly connector.


b.

Disconnect the A34 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G80-24 (S5-3) - A34-3 (+) Always Below 1 Ω
G80-24 (S5-3) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the G80 air conditioning amplifier assembly connector.


b.

Disconnect the A34 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G80-5 (SG-2) - A34-1 (-) Always Below 1 Ω
G80-5 (SG-2) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the A34 air conditioner pressure sensor connector.


b.

Disconnect the G80 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-2 (PR) - G80-7 (PRE) Always Below 1 Ω
A34-2 (PR) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

8.INSPECT FOR AIR CONDITIONING SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.INSPECT FOR AIR CONDITIONING SYSTEM LEAK
a.

Install a manifold gauge set.


b.

Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.


c.

Evacuate the air conditioning system and check that vacuum can be maintained in it.

HINT:

If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.



Result:
Result
Vacuum can be maintained in the air conditioning system
Vacuum cannot be maintained in the air conditioning system



Vacuum can be maintained in the air conditioning system

9.CHARGE SYSTEM WITH REFRIGERANT

Vacuum cannot be maintained in the air conditioning system

11.REPAIR AIR CONDITIONING SYSTEM LEAK
9.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.



Result:
Proceed to
NEXT



NEXT

10.CHECK FOR DTC
10.CHECK FOR DTC
a.

Check for DTCs when the following conditions are satisfied.

Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


Result:
Proceed to
DTC B1423 is not output
DTC B1423 is output


NOTICE:

If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.




DTC B1423 is not output

END

DTC B1423 is output

12.CHECK AIR CONDITIONER PRESSURE SENSOR
11.REPAIR AIR CONDITIONING SYSTEM LEAK
a.

Identify the area where refrigerant leaks from.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT


b.

Repair the identified area of the air conditioning system.


c.

Evacuate the air conditioning system.


Result:
Proceed to
NEXT



NEXT

12.CHECK AIR CONDITIONER PRESSURE SENSOR
a.
E220539C20
1.5,0.229 1.99,0.51 0.49,0.281 0.875,1.833 1.208,1.156 false 2.406,1.802 1.958,1.156 false 0.198,0.167 0.604,0.5 0.406,0.333 10 *a 0.75,1.844 1.302,2.073 0.552,0.229 10 PRE 2.26,1.823 2.906,2.063 0.646,0.24 10 SG-2 1.625,0.271 2.083,0.469 0.458,0.198 10 G80
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Install a manifold gauge set.


b.

Connect the A34 air conditioner pressure sensor connector.


c.

Turn the ignition switch to ON.


d.

Turn the A/C switch on.


e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G80-7 (PRE) - G80-5 (SG-2) Engine running
Air conditioning system operating
Refrigerant pressure: Normal pressure (less than 3025 kPa [30.9 kgf/cm2, 439 psi] and more than 176 kPa [1.8 kgf/cm2, 25 psi])
0.74 to 4.62 V



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

14.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.



Result:
Proceed to
NEXT



NEXT

15.CHECK FOR DTC
15.CHECK FOR DTC
a.

Check for DTCs when the following conditions are satisfied.

Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs. If the DTC is not output after this work, it indicates that the cooler dryer in the cooler condenser assembly is not able to absorb moisture in the refrigerant cycle. It is necessary to replace the cooler dryer in order to complete the repair.




Result:
Proceed to
DTC B1423 is not output
DTC B1423 is output



DTC B1423 is not output

REPLACE COOLER CONDENSER ASSEMBLY

DTC B1423 is output

16.REPLACE COOLER EXPANSION VALVE
16.REPLACE COOLER EXPANSION VALVE
a.

Replace the cooler expansion valve with a new one.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL

HINT:

Replace the cooler expansion valve with a new one because the cooler expansion valve is either stuck or clogged.



Result:
Proceed to
NEXT



NEXT

17.CHARGE SYSTEM WITH REFRIGERANT
17.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.



Result:
Proceed to
NEXT



NEXT

18.CHECK FOR DTC
18.CHECK FOR DTC
a.

Check for DTCs when the following conditions are satisfied.

Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the cooler expansion valve with a new or known good one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other foreign matter. In this case, clean or replace the cooler condenser assembly or pipes.



Result:
Proceed to
DTC B1423 is not output
DTC B1423 is output




DTC B1423 is not output

END (COOLER EXPANSION VALVE IS DEFECTIVE)

DTC B1423 is output

CLEAN OR REPLACE COOLER CONDENSER ASSEMBLY OR PIPE