Refer to "SRS Warning Light Remains ON"
Refer to "SRS Warning Light Remains ON"
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
After replacing the airbag sensor assembly, refer to initialization.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Measure the voltage of the battery.
11 to 14 V
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the combination meter assembly.
| Proceed to |
|---|
| The connectors are properly connected |
| The connectors are not properly connected |
The connectors are properly connected
The connectors are not properly connected
Turn the ignition switch off.
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the G16 connector from the combination meter assembly.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-39 (IG+) - G16-21 (ET) | Ignition switch ON | 11 to 14 V |
| G16-40 (B) - G16-21 (ET) | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-21 (ET) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Connect the connector to the combination meter assembly.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Check the SRS warning light condition.
After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on.
The primary check period is approximately 6 seconds after the ignition switch is turned to ON.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING