When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.
Data List items:
Oper Permission (Battery)
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
Oper Permission (Battery Current)
Oper Permission (Integrated Current)
Oper Prohibition (Jump Start)
Oper Prohibition (Manual Start)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Trouble Codes.
Read the DTCs.
| Proceed to |
|---|
| DTC is not output |
| DTC is output |
DTC is not output
DTC is output
Enter the following menus: Powertrain / Stop and Start / Data List.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed | - |
| Oper Permission (Start Min Volt 1) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or less and the minimum voltage at starter ON is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 2) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage at starter ON is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 3) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or less and the minimum voltage right after engine cranking is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 4) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage right after engine cranking is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Battery Current) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery discharge current is -125 A or less | Engine stop and start ECU calculated value |
| Oper Permission (Integrated Current) | Permission of stop and start control based on the integrated current value conditions | NG/OK | OK: Integrated current value more than specified | The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature. |
| Oper Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit/Prohibit | Prohibit: Engine started with the engine hood open and the ignition switch turned to START | When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off. |
| Oper Prohibition (Manual Start) | Prohibition of stop and start control based on the manual start conditions | Permit/Prohibit | Prohibit: During manual start | When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
Conditions for Manual Start: ·
Clutch start switch OFF or vehicle speed signal input ·
Neutral position switch OFF ·
Starter signal OFF |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Oper Permission (Start Min Volt 1) |
| Oper Permission (Start Min Volt 2) |
| Oper Permission (Start Min Volt 3) |
| Oper Permission (Start Min Volt 4) |
| Oper Permission (Battery Current) |
| Oper Permission (Integrated Current) |
| Oper Prohibition (Jump Start) |
| Oper Prohibition (Manual Start) |
| Proceed to |
|---|
| NEXT |
NEXT
Check whether stop and start control was prohibited based on the battery conditions or other conditions.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
NG is displayed
OK is displayed
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 1AD-FTV)>SYSTEM DESCRIPTION
Check whether stop and start control was prohibited based on the battery charge control mode.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Status of Battery Charge Control | Battery charge control status | Change Control Condition Mode/Stop and Start Standalone/Refresh Charge Mode/Stop and Start Restriction Mode/Temperature High/Low Mode/Abnormal Mode/Battery Condition Judgment Mode/Low Temperature Mode | - | - |
| Tester Display |
|---|
| Status of Battery Charge Control |
| Result | Proceed to |
|---|---|
| "Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed | A |
| "Refresh Charge Mode" is displayed | B |
| "Battery Condition Judgment Mode" is displayed | C |
| "Abnormal Mode" is displayed | D |
If "Refresh Charge Mode" is displayed, leave the vehicle idling for 30 to 60 minutes.
A
B
C
D
Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Start Min Volt 1) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or less and the minimum voltage at starter ON is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 2) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage at starter ON is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 3) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or less and the minimum voltage right after engine cranking is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 4) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage right after engine cranking is the threshold value or higher | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Tester Display |
|---|
| Oper Permission (Start Min Volt 1) |
| Oper Permission (Start Min Volt 2) |
| Oper Permission (Start Min Volt 3) |
| Oper Permission (Start Min Volt 4) |
| Proceed to |
|---|
| OK is displayed for 2 or more items |
| OK is displayed for 1 item or none |
The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Temp (Start) | Battery temperature at engine start | Min.: -40°C (-40°F), Max.: 100°C (212°F) | Same as temperature around battery at engine start (after engine start) | - |
| Ambient Temp Sensor | Ambient temperature | Min.: -30°C (-22°F), Max.: 50°C (122°F) | Close to ambient temperature | - |
| Min Voltage(Cranking) | Minimum battery voltage while engine cranking (incurrent trip) | Min.: 0 V, Max.: 327.67 V | 6 to 11 V | Lowest battery voltage measured in a 5 second period after the starter starts operating. |
| Min Volt(After Cranking) | Minimum battery voltage just after engine cranking | Min.: 0 V, Max.: 327.67 V | 6 to 11 V | Minimum battery voltage while starter driving |
| Tester Display |
|---|
| Battery Temp (Start) |
| Ambient Temp Sensor |
| Min Voltage(Cranking) |
| Min Volt(After Cranking) |
| Tester Display | Starting Battery Voltage | Battery Temperature*1 |
|---|---|---|
| Oper Permission (Start Min Volt 1)*2 | 8.14 V or higher | 0°C (32°F) or less |
| Oper Permission (Start Min Volt 2)*2 | 8.14 V or higher | Higher than 0°C (32°F) |
| Oper Permission (Start Min Volt 3)*3 | 8.14 V or higher | 0°C (32°F) or less |
| Oper Permission (Start Min Volt 4)*3 | 8.14 V or higher | Higher than 0°C (32°F) |
*1: Read the Data List items "Battery Temp (Start)" and "Ambient Temp Sensor" when checking the battery temperature.
*2: Operation is permitted when the minimum voltage is 8.14 V or more when 0.0049 seconds have elapsed after cranking the engine.
*3: Operation is permitted when the minimum voltage is 8.14 V or more right after cranking the engine.
OK is displayed for 2 or more items
OK is displayed for 1 item or none
Check whether the stop and start control was prohibited based on the battery discharge current battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery Current) | Permission of stop and start control based on the battery conditions | NG/OK | OK: Battery discharge current is -125 A or less | Engine stop and start ECU calculated value |
| Tester Display |
|---|
| Oper Permission (Battery Current) |
| Proceed to |
|---|
| OK is displayed |
| NG is displayed |
The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Current | Battery current | Min.: 0 A, Max.: 124.99 A | - | - |
| Tester Display |
|---|
| Battery Current |
| Tester Display | Battery Current |
|---|---|
| Oper Permission (Battery Current) | -125 A or less |
OK is displayed
NG is displayed
Check whether the stop and start control was prohibited based on the integrated current value battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Integrated Current) | Permission of stop and start control based on the integrated current value conditions | NG/OK | OK: Integrated current value more than specified | The condition is judged based on the integrated current value.
The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature. |
| Tester Display |
|---|
| Oper Permission (Integrated Current) |
| Proceed to |
|---|
| OK is displayed |
| NG is displayed |
OK is displayed
NG is displayed
Check the operation of the backup boost converter.
Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC and BBC Check Result.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| State of BBC | Backup boost converter status | Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Resetstatus | Normal: Backup boost converter operating normally | ·
Cycle Err: ·
Abnormal output voltage cycle is detected ·
Overvol: ·
When the ignition switch is ON: 1.
Overvoltage is detected at the control IC power source within the backup boost converter 2.
Overheating is detected at the control IC power source within the backup boost converter ·
When boosting: 1.
Error is detected in the feedback circuit in the backup boost converter 2.
Too high or low output voltage ·
Overload: ·
Overcurrent is detected. ·
Low Vol: ·
A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON. ·
Duty Err: ·
Abnormal duty ratio is detected |
| BBC Check Result | Backup boost converter check result | Normal / Abnormal | - | - |
| Tester Display |
|---|
| State of BBC |
| BBC Check Result |
| Proceed to |
|---|
| Normal is displayed |
| Normal is not displayed |
Normal is displayed
Normal is not displayed
Check whether stop and start control was prohibited based on the jump start battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit / Prohibit | Prohibit: Engine started with the engine hood open and the ignition switch turned to START | When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off. |
| Tester Display |
|---|
| Oper Prohibition (Jump Start) |
| Proceed to |
|---|
| Permit is displayed |
| Prohibit is displayed |
The Data List item "Oper Permission (Jump Start)" is judged Permit or Prohibit according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hood Courtesy Switch | Hood courtesy switch signal | ON / OFF | ON: Engine hood closed
OFF: Engine hood opened |
- |
| Oper Permission (Engine Hood Closed) | Permission of stop and start control based on the engine hood open/close conditions | NG / OK | OK: Engine hood closed | - |
| Tester Display |
|---|
| Hood Courtesy Switch |
| Oper Permission (Engine Hood Closed) |
| Tester Display | Conditions |
|---|---|
| Oper Prohibition (Jump Start) | ON (Engine hood closed) is displayed for Hood Courtesy Switch |
| OK (Engine Hood Closed) is displayed for Oper Permission (Engine Hood Closed) |
Permit is displayed
Prohibit is displayed
Check whether the stop and start control was prohibited based on the manual start battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Manual Start).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Prohibition (Manual Start) | Prohibition of stop and start control based on the manual start conditions | Permit / Prohibit | Prohibit: During manual start | When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
Conditions for Manual Start: ·
Clutch start switch OFF or vehicle speed signal input ·
Neutral position switch OFF ·
Starter signal OFF |
| Tester Display |
|---|
| Oper Prohibition (Manual Start) |
| Proceed to |
|---|
| Permit is displayed |
| Prohibit is displayed |
If Prohibit is displayed, start the engine using a key.
Permit is displayed
Prohibit is displayed
Check whether the stop and start control was prohibited based on the battery temperature battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery conditions | NG / OK | OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Temp (Start) | Battery temperature at engine start | Min.: -40°C (-40°F), Max.: 100°C (212°F) | Same as temperature around battery at engine start (after engine start) | - |
| Ambient Temp Sensor | Ambient temperature | Min.: -30°C (-22°F), Max.: 50°C (122°F) | Close to ambient temperature | - |
| Tester Display |
|---|
| Battery Temp (Start) |
| Ambient Temp Sensor |
| Tester Display | Battery Temperature* |
|---|---|
| Oper Permission (Battery Current) | Current battery temperature is between -10°C (14°F) and 70°C (158°F) |
*: Read the Data List items "Battery Temp (Start)" and "Ambient Temp Sensor" when checking the battery temperature.
NG is displayed
OK is displayed
Check the battery temperature.
Enter the following menus: Powertrain / Stop and Start / Data List.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Temp (Start) | Battery temperature at engine start | Min.: -40°C (-40°F), Max.: 100°C (212°F) | Same as temperature around battery at engine start (after engine start) | - |
| Ambient Temp Sensor | Ambient temperature | Min.: -30°C (-22°F), Max.: 50°C (122°F) | Close to ambient temperature | - |
| Tester Display |
|---|
| Battery Temp (Start) |
| Ambient Temp Sensor |
| Proceed to |
|---|
| Battery temperature is as specified |
| Battery temperature is not as specified |
If the battery temperature is not as specified, leave the battery under room temperature conditions until its temperature becomes as specified.
Battery temperature is as specified
Battery temperature is not as specified
Check whether stop and start control was prohibited based on the alternator status battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery conditions | NG / OK | OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Alternator Status | Alternator power generation status | Normal / Abnormal | Normal: Alternator operation normal | - |
| Tester Display |
|---|
| Alternator Status |
| Tester Display | Conditions |
|---|---|
| Oper Permission (Battery) | Normal is displayed for Alternator Status (Alternator is generating power) |
| Charge indicator light is off when the engine is running (Alternator is generating power) |
NG is displayed
OK is displayed
Check the power generation status of the alternator.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Alternator Status | Alternator power generation status | Normal / Abnormal | Normal: Alternator operation normal | - |
| Tester Display |
|---|
| Alternator Status |
| Proceed to |
|---|
| Normal is displayed |
| Abnormal is displayed |
Normal is displayed
Abnormal is displayed
Check whether stop and start control was prohibited based on the idling stop rate battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery conditions | NG / OK | OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Idling Stop Rate | Rate of the idling stop time to the entire ignition switch ON time | Min.: 0%, Max.: 100% | - | - |
| Tester Display |
|---|
| Idling Stop Rate |
| Tester Display | Idling Stop Rate |
|---|---|
| Oper Permission (Battery) | 39% or less |
When the idling stop rate exceeds 40%, stop and start control is permitted when the rate drops to 37% or less.
NG is displayed
OK is displayed
Check the idling stop rate.
Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Idling Stop Rate | Rate of the idling stop time to the entire ignition switch ON time | Min.: 0%, Max.: 100% | - | - |
| Tester Display |
|---|
| Idling Stop Rate |
| Proceed to |
|---|
| 40% or higher |
| 39% or less |
When the idling stop rate exceeds 40%, turn the ignition switch off and then start the engine again. If NG is still displayed for the Data List item "Oper Permission (Battery)", the battery may be discharged or deteriorated. Check the battery condition and recharge or replace the battery.
40% or higher
39% or less
Check the engine hood courtesy switch (hood lock assembly).
Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hood Courtesy Switch | Hood courtesy switch signal | ON / OFF | ON: Engine hood closed
OFF: Engine hood opened |
- |
| Tester Display |
|---|
| Hood Courtesy Switch |
| Proceed to |
|---|
| OK |
| NG |
When the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.
OK
NG
Judge the battery condition based on the integrated current value.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.
Check the following items on the GTS display.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Integrated Current | Battery integrated current | Min.: -268434.45 A-sec, Max.: 268435.45 A-sec | Differs according to the vehicle condition (charge / discharge conditions) | - |
| Tester Display |
|---|
| Integrated Current |
Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Temp (Start) | Battery temperature at engine start | Min.: -40°C (-40°F), Max.: 100°C (212°F) | Same as temperature around battery at engine start (after engine start) | - |
| Idle | Engine idling status | ON / OFF | ON: Accelerator pedal fully released
OFF: Accelerator pedal depressed |
This is sent from the ECM. |
| Battery Current | Battery current | Min.: 0 A, Max.: 124.99 A | - | - |
| Ambient Temp Sensor | Ambient temperature | Min.: -30°C (-22°F), Max.: 50°C (122°F) | Close to ambient air temperature | - |
| Integrated Current | Battery integrated current | Min.: -268434.45 A-sec, Max.: 268435.45 A-sec | Differs according to the vehicle condition (charge / discharge conditions) | - |
| Tester Display |
|---|
| Battery Temp (Start) |
| Idle |
| Battery Current |
| Ambient Temp Sensor |
| Integrated Current |
| Battery Temperature | Tester Display | Integrated Current | Proceed to |
|---|---|---|---|
| -1°C (30.2°F) or higher, or 65°C (149°F) or less | Integrated Current | Below -5299 A-sec | A |
| -1°C (30.2°F) or higher, or 65°C (149°F) or less | Below 0 A-sec | A | |
| Below -1°C (30.2°F) or -15°C (5°F) or higher, or 65°C (149°F) or higher, or 75°C (167°F) or less | |||
| Below -15°C (5°F) or higher than 75°C (167°F) | - | B |
| Result | Cause | Action to be Taken |
|---|---|---|
| A | Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery | Check the battery condition and recharge or replace the battery |
| B | Integrated current value is limited for stop and start control due to battery temperature (too high/low) | Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery. |
After recharging the battery, initialize the integrated current value* and drive the vehicle until stop and start control operation is permitted (approximately 15 to 40 minutes).
*: Disconnect the cables from the battery, wait for 30 seconds or more and then reconnect the cables.
When the battery sensor current value is normal, recharge or replace the battery
| Proceed to |
|---|
| NEXT |
NEXT