The battery thermometer sensor detects the battery temperature.
The battery current sensor has a built-in thermistor with a resistance that changes in response to changes in the battery temperature.
When the battery temperature is low the thermistor resistance increases, and when the temperature is high the resistance decreases.
The battery thermometer sensor is connected to the ECM.
A power supply voltage of 5 V is supplied to the battery temperature sensor from terminal THB of the ECM via resistor R.
As resistor R and the battery thermometer sensor are connected in series, when the resistance changes in response to changes in the battery temperature, the electric potential at terminal THB also changes.
Based on this signal, the ECM protects the battery by reducing the charge current when the battery temperature is high.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0516 | Battery Temperature Sensor Circuit Low | Battery thermometer sensor output value is abnormally low for 0.5 seconds or more with the ignition switch ON
(1 trip detection logic) |
·
Battery current sensor assembly (battery thermometer sensor) ·
ECM ·
Wire harness or connector |
Does not come on | DTC stored |
| P0517 | Battery Temperature Sensor Circuit High | Battery thermometer sensor output value is abnormally high for 0.5 seconds or more with the ignition switch ON
(1 trip detection logic) |
·
Battery current sensor assembly (battery thermometer sensor) ·
ECM ·
Wire harness or connector |
Does not come on | DTC stored |
Inspect the battery current sensor assembly.
Click herePower Source / Network>2AD-FTV BATTERY / CHARGING>BATTERY CURRENT SENSOR>INSPECTION
| Result |
|---|
| OK |
| NG |
OK
NG
Disconnect the B76 ECM connector.
Disconnect the B72 battery current sensor assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B76-77 (EIB) - B72-4 (E2) | Always | Below 1 Ω |
| B76-75 (VCIB) - B72-2 (VC5) | Always | Below 1 Ω |
| B76-115 (THB) - B72-1 (THB) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B76-77 (EIB) or B72-4 (E2) - Body ground | Always | 10 kΩ or higher |
| B76-75 (VCIB) or B72-2 (VC5) - Body ground | Always | 10 kΩ or higher |
| B76-115 (THB) or B72-1 (THB) - Body ground | Always | 10 kΩ or higher |
| Result |
|---|
| OK |
| NG |
OK
NG