Home › Power Source / Network › 2AR-FE BATTERY / CHARGING › BATTERY CURRENT SENSOR(w/ Battery Current Sensor)
RM3090E _57 Power Source / Network _008403 2AR-FE BATTERY / CHARGING _0056336 BATTERY CURRENT SENSOR(w/ Battery Current Sensor) A

2AR-FE BATTERY / CHARGING  BATTERY CURRENT SENSOR(w/ Battery Current Sensor)  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 28850 2.REMOVE GENERATOR CONTROL ECU ASSEMBLY (BATTERY CURRENT SENSOR)

a.
A300510N01
1.281,0.063 1.438,0.26 0.156,0.198 10 A 2,0.438 2.156,0.635 0.156,0.198 10 B

Remove nut B and disconnect the No. 3 engine wire from the generator control ECU assembly.

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION



b.

Disconnect the connector from the generator control ECU assembly.


c.

Remove nut A and disconnect the generator contol ECU assembly from the negative (-) battery terminal.


d.

Loosen the nut and remove the negative (-) battery terminal from the battery.