Home › Power Source / Network › 2AR-FE BATTERY / CHARGING › BATTERY CURRENT SENSOR(w/ Battery Current Sensor)
RM3090E _57 Power Source / Network _008403 2AR-FE BATTERY / CHARGING _0056336 BATTERY CURRENT SENSOR(w/ Battery Current Sensor) A

2AR-FE BATTERY / CHARGING  BATTERY CURRENT SENSOR(w/ Battery Current Sensor)  INSTALLATION  


PROCEDURE

Hide 28850 1.INSTALL GENERATOR CONTROL ECU ASSEMBLY (BATTERY CURRENT SENSOR)

a.

Install the negative (-) battery terminal to the battery and tighten the nut.

Torque:
5.4 N*m (55 kgf*cm, 48 in.*lbf)


b.
A300510N01
1.281,0.063 1.438,0.26 0.156,0.198 10 A 2,0.438 2.156,0.635 0.156,0.198 10 B

Connect the generator control ECU assembly to the negative (-) battery terminal with nut A.

Torque:
7.6 N*m (77 kgf*cm, 67 in.*lbf)


c.

Connect the No. 3 engine wire to the generator control ECU assembly with nut B.

Torque:
7.6 N*m (77 kgf*cm, 67 in.*lbf)


d.

Connect the connector to the generator control ECU assembly.

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION