Home › Engine / Hybrid System › STOP AND START › STOP AND START SYSTEM(for 3ZR-FAE) › 2015.04–2015.10
RM3090E _51 Engine / Hybrid System _009049 STOP AND START _0166176 STOP AND START SYSTEM(for 3ZR-FAE) J

STOP AND START  STOP AND START SYSTEM(for 3ZR-FAE)  Neutral Position Switch Circuit  


DESCRIPTION

The engine stop and start ECU uses the park/neutral position switch assembly installed to the continuously variable transaxle assembly to detect when the shift lever is in P or N.

PROCEDURE

1.READ VALUE USING GTS (NEUTRAL SWITCH)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Stop and Start / Data List / Neutral Switch.


e.

In accordance with the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display
Neutral Switch
50003 227 9
OK:
Tester Display Condition Normal Condition
Neutral Switch Shift lever in P or N ON
Shift lever not in P or N OFF



Result:
Proceed to
OK
NG



OK

GO TO PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

2.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
2.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
a.

Inspect the park/neutral position switch assembly.

Click hereDrivetrain>K114F MULTIDRIVE / CVT>PARK / NEUTRAL POSITION SWITCH>INSPECTION


Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - PARK/NEUTRAL POSITION SWITCH ASSEMBLY)

NG

REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY

3.CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - PARK/NEUTRAL POSITION SWITCH ASSEMBLY)
a.

Disconnect the A66 engine stop and start ECU connector.


b.

Disconnect the B36 park/neutral position switch assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A66-21 (STA) - B36-9 (L) Always Below 1 Ω
A66-28 (CLL) - B36-4 (B) Always Below 1 Ω
A66-21 (STA) - Body ground Always 80 to 180 Ω
A66-28 (CLL) - Body ground Always 10 kΩ or higher
B36-9 (L) - Body ground Always 80 to 180 Ω
B36-4 (B) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR