The CVT fluid temperature sensor converts the fluid temperature into a resistance value which is detected by the ECM.
The sensor resistance changes with the CVT fluid temperature. As the temperature rises, the sensor resistance decreases. The ECM applies voltage to the temperature sensor through ECM terminal THO1 and calculates the fluid temperature based on the voltage signal.
The CVT fluid temperature is likely to increase under conditions such as towing, climbing hills and in traffic.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0712 | Transmission Fluid Temperature Sensor "A" Circuit Low Input | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
1.
Always 2.
Short in CVT fluid temperature sensor circuit 3.
0.5 seconds 4.
1-trip detection logic |
·
Harness or connector ·
Continuously variable transaxle assembly (CVT fluid temperature sensor) ·
ECM |
Comes on | DTC stored |
| P0713 | Transmission Fluid Temperature Sensor "A" Circuit High Input | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
DTC Detection Condition 1: 1.
10 seconds or more after starting engine (Engine coolant temperature and intake air temperature at engine start are higher than -29.375°C (-20.875°F)) 2.
Open in CVT fluid temperature sensor circuit 3.
0.5 seconds 4.
1-trip detection logic DTC Detection Condition 2: 1.
15 minutes or more after starting engine (Engine coolant temperature and intake air temperature at engine start are at -29.375°C (-20.875°F) or less) 2.
Open in CVT fluid temperature sensor circuit 3.
0.5 seconds 4.
1-trip detection logic |
·
Harness or connector ·
Continuously variable transaxle assembly (CVT fluid temperature sensor) ·
ECM |
Comes on | DTC stored |
The CVT fluid temperature sensor converts the CVT fluid temperature to an electrical resistance value. Based on the resistance, the ECM determines the CVT fluid temperature and detects an open or short circuit in the CVT fluid temperature circuit. If the resistance value of the CVT fluid temperature is below 79 Ω*1 or higher than 156 kΩ*2, the ECM interprets this as a fault in the CVT fluid sensor or wiring. The ECM illuminates the MIL and stores a DTC.
*1: 150°C (302°F) or higher is indicated regardless of the actual CVT fluid temperature.
*2: -40°C (-40°F) is indicated regardless of the actual CVT fluid temperature.
The CVT fluid temperature can be checked on the GTS display.
Perform initialization when parts related to the continuously variable transaxle are replaced.
Click hereDrivetrain>K114F MULTIDRIVE / CVT>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>INITIALIZATION
Check that no DTCs are stored after performing initialization.
Click hereDrivetrain>K114F MULTIDRIVE / CVT>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>DTC CHECK / CLEAR
Warm up the engine.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Primary.
In accordance with the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| A/T Oil Temperature 1 | CVT fluid temperature sensor value | Min.: -40°C (-40°F)
Max.: 150°C (302°F) |
·
After stall speed test: approximately 100°C (212°F) ·
Equal to ambient temperature after cold soak |
If the value is -40°C (-40°F) or 150°C (302°F) or higher, the CVT fluid temperature sensor circuit is open or shorted. |
| Tester Display |
|---|
| A/T Oil Temperature 1 |
| Result | Proceed to |
|---|---|
| Data display is not within Normal Condition range | A |
| Data display is within Normal Condition range | B |
A
B
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (THO) - 7 (E2) | Always | 79 Ω to 156 kΩ |
| 1 (THO) - Body ground and other terminals | Always | 10 kΩ or higher |
| 7 (E2) - Body ground and other terminals | Always | 10 kΩ or higher |
If the resistance is outside the specified range at any of the CVT fluid temperatures shown in the table below, the driveability of the vehicle may be affected.
| CVT Fluid Temperature | Specified Condition |
|---|---|
| 10°C (50°F) | 5.6 to 7.3 kΩ |
| 25°C (77°F) | 3.5 kΩ |
| 110°C (230°F) | 0.22 to 0.27 kΩ |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B93-129 (THO1) - B93-130 (ETHO) | Always | 79 Ω to 156 kΩ |
| B93-129 (THO1) - Body ground and other terminals | Always | 10 kΩ or higher |
| B93-130 (ETHO) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the ECM.
Click hereEngine / Hybrid System>3ZR-FAE ENGINE CONTROL>ECM>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Replace the continuously variable transaxle assembly.
Click hereDrivetrain>K114F MULTIDRIVE / CVT>CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Replace the ECM.
Click hereEngine / Hybrid System>3ZR-FAE ENGINE CONTROL>ECM>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT