Home › Power Source / Network › 2AR-FE BATTERY / CHARGING › GENERATOR(for 150 A Type) › from 2015.10
RM3090E _57 Power Source / Network _008403 2AR-FE BATTERY / CHARGING _0208709 GENERATOR(for 150 A Type) A

2AR-FE BATTERY / CHARGING  GENERATOR(for 150 A Type)  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 16361A 3.REMOVE FAN AND GENERATOR V BELT

Hide 4.REMOVE WIRE HARNESS CLAMP BRACKET

A298986

a.

Detach the wire harness clamp from the clamp bracket.


b.

Remove the bolt and clamp bracket.


Hide 27020 5.REMOVE GENERATOR ASSEMBLY

a.
A298987

Disconnect the generator connector.


b.

Remove the terminal cap.


c.

Remove the nut and disconnect the generator wire.


d.

Remove the bolt and wire harness clamp bracket.


e.
A370703

Remove the 2 bolts and generator assembly.