If the engine stop and start ECU detects that there is an open circuit when signals such as boost, standby request or overheating cannot be sent to the backup boost converter control IC from the stop and start control IC in the engine stop and start ECU.
When a CPU duty error is detected, the engine stop and start ECU stores DTC P060A and blinks the stop and start cancel indicator light.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | Memory |
|---|---|---|---|---|---|
| P060A | Internal Control Module Monitoring Processor Performance | The following condition continues for 1 second or more (2 trip detection logic):
·
CPU duty error is detected. |
·
Wire harness or connector ·
Engine stop and start ECU |
Blinks | DTC stored |
DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 2WW)>DTC CHECK / CLEAR
CONFIRMATION AFTER TROUBLESHOOTING
If the cable is disconnected from the negative (-) battery terminal, stop and start control is prohibited until refresh charge is completed. In this case, drive the vehicle approximately 5 to 60 minutes until refresh charge is completed and stop and start control operation is permitted.
Allow the engine to idle for 3 minutes after the engine warms up and check that the engine speed is within 50 rpm of the target idle speed.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 2WW)>DTC CHECK / CLEAR
Start the engine and warm it up.
Drive the vehicle at 7 km/h (4.3 mph) or more.
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Stop the vehicle, move the shift lever to neutral and release the clutch pedal.
Keep the engine stopped by stop and start control for 1 second or more.
Depress the clutch pedal and start the engine.
Check that DTCs are not output.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 2WW)>DTC CHECK / CLEAR
STOP AND START SYSTEM OPERATION CHECK
If the cable is disconnected from the negative (-) battery terminal, stop and start control is prohibited until refresh charge is completed. In this case, drive the vehicle approximately 5 to 60 minutes until refresh charge is completed and stop and start control operation is permitted.
Start the engine and warm it up.
Turn the air conditioning system off.
Drive the vehicle at 7 km/h (4.3 mph) or more.
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Stop the vehicle, move the shift lever to neutral and release the clutch pedal.
Allow the engine to stop by stop and start control.
Depress the clutch pedal and start the engine.
Before replacing the engine stop and start ECU, read the number of starter operations and write it into a new engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 2WW)>REGISTRATION
After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 2WW)>REGISTRATION
After replacing the engine stop and start ECU or airbag sensor assembly, perform deceleration sensor zero point clear and calibration.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 2WW)>REGISTRATION
Inspect the fuses for circuits related to this system before performing the following procedure.
Using the GTS, read the freeze frame data before troubleshooting. System condition information is recorded as freeze frame data the moment a DTC is stored. This information can be useful when troubleshooting.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 2WW)>FREEZE FRAME DATA
Disconnect the engine stop and start ECU connector.
| *a | Front view of wire harness connector
(to Engine Stop and Start ECU) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A86-1 (BIN2) - Body ground | Always | 9.5 to 14 V |
| A86-3 (BIN1) - Body ground | Always | 9.5 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A86 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A86-2 (GND2) - Body ground | Always | Below 1 Ω |
| A86-8 (GND1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK